[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B050) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<50 A rated current II=600 A Short-circuit protection Ir=50A overcurrent release for system protection without connection accessories without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B025) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<25 A rated current II=300 A Short-circuit protection Ir=25 A overcurrent release for system protection without connection accessories without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250 UL Type FG (CAT NO. HFK3T250) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release ETU, LSI TU=40 °C In=250 A, Rated current ISD=1.5-10xIR, II=11xIn Short-circuit protection IR=70-250A overcurrent release for system protection without connection accessories Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=160 A, Rated current Ir=125...160 A, Overload protection, II=800...1600 A, Short-circuit protection N unprotected with screw terminal without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=315 A, Rated current Ir=250...315 A, Overload protection, II=1575...3150 A, Short-circuit protection N unprotected without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=315 A, Rated current Ir=250...315 A, Overload protection, II=1575...3150 A, Short-circuit protection N unprotected Undervoltage release 380...415 V AC Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 4-pole, non-automatic air circuit breaker Overcurrent release magnetic In=400 A, Rated current II=4000 A, Short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU20, LSI In=160 A, Rated current IR=64...160 A, Overload protection, ISD=1.5 to 10xIR, II=11xIn short-circuit protection Undervoltage release 220...250 V AC without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=20 A, Rated current II=300 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=50 A, Rated current Ir=40...50 A, Overload protection II=600 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=50 A, Rated current Ir=40...50 A, Overload protection II=300...600 A, Short-circuit protection protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=63 A, Rated current Ir=50...63A, Overload protection, II=300...600 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=80 A, With reduced Ir=63...80 A, Overload protection, II=400...800 A, short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=100 A, Rated current II=750...1500 A, short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=160 A, Rated current II=1250...2500 A, Short-circuit protection with screw terminal without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400H High switching capacity Icu=70 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=250 A, Rated current II=2000...4000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL630N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=500 A, Rated current Ir=400...500 A, Overload protection, II=2500...5000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL630H High switching capacity Icu=70 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=500 A, Rated current II=3250...6300 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL800N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release ETU10, LI In=800 A, Rated current Ir=320...800 A, Overload protection, II=1.25 to 8xIn, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL1250N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release ETU10, LI In=1000 A, Rated current Ir=400...1000 A, Overload protection, II=1.25 to 11xIn, Short-circuit protection without auxiliary release without auxiliary/alarm switch