• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL150X UL

Showing 961-972 of 972 Products

3VL4740-2SB36-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL2705-2DC36-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, protection, with screw terminals without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL5763-2SB36-0AE1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL2710-1SP36-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=100A, rated current IR=40...100A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL2716-3DC33-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL2716-3DC33-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL4731-3DC36-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL3725-3DC36-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1200...2500A, short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL6780-3ME36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch

3VL2506-3PB30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. LDK3R060) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LI TA=40°C In=60A, rated current II=1.25-11 xIN, short-circuit protection Ir=30-60A Electronic Trip Unit for line protection without connection accessories without auxiliary/alarm switch

3VL4731-1SL36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL3725-2EM46-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit, TM, LI In=250A, rated current IR=200...250A, overload prot. II=1250...2500A, short-circuit protection N protected (100%) without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)