[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250 UL Type FG (CAT NO. HFK3B225) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=225 A, Rated current II=1250...2500 A Short-circuit protection Ir=225 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250 UL Type FG (CAT NO. HFK3B100) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=100 A, Rated current II=625...1250 A Short-circuit protection Ir=100 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150 UL Type DG (CAT NO. HDK3B070) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=70 A, Rated current II=450...700 A Short-circuit protection Ir=70 A overcurrent release for system protection without connection accessories without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150 UL Type DG (CAT NO. HDK3B110) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=110 A, Rated current II=550...1100 A Short-circuit protection Ir=110 A overcurrent release for system protection without connection accessories without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150 UL Type DG (CAT NO. HDK3B080) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=80 A, Rated current II=450...800 A Short-circuit protection Ir=80 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250L Very high switching capacity Icu=100 kA, 415 V AC 3-pole, Motor/generator protection Overcurrent release ETU10M, LI In=250 A, Rated current Ir=100...250 A, Overload protection, II=1.25 to 11xIn, Short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, Motor/generator protection Overcurrent release ETU10M, LI In=160 A, Rated current IR=64...160 A, Overload protection, II=1.25 to 11xIn, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=200A, Rated current Ir=160...200 A, Overload protection, II=1000...2000 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL1600 UL; Type PG (CAT NO. HPX3T160) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V, (molded case circuit breaker) Overcurrent release ETU, LSI TU=40 °C In=1600 A, Rated current ISD=1.5 to 8 xIR, II=6xIn Short-circuit protection IR=700-1600A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU10, LI In=63 A, Rated current Ir=25...63 A, Overload protection, II=1.25 to 11xIn, Short-circuit protection without auxiliary release ETU communication-capable Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B125) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 Standard switching capacity 3-pole, NEMA rating 35 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<125 A rated current II=1000 A Short-circuit protection Ir=125 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=315 A, Rated current Ir=250...315 A, Overload protection, II=1575...3150 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=125 A, Rated current Ir=100...125 A, Overload protection, II=625...1250 A, short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=20 A, Rated current Ir=16...20 A, Overload protection II=300 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=40 A, Rated current Ir=32...40 A, Overload protection II=600 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=63 A, Rated current Ir=50...63A, Overload protection II=600 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=80 A, Rated current Ir=63...80A, Overload protection II=1000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=100 A, Rated current Ir=80...100A, Overload protection II=1000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=125 A, Rated current Ir=100...125 A, Overload protection II=1000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=250 A, Rated current Ir=200...250 A, Overload protection, II=1200...2500 A, short-circuit protection without auxiliary release without auxiliary/alarm switch