Showing 61-80 of 972 Products

3VL4740-1DC36-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=400 A, Rated current Ir=320...400 A, Overload protection, II=2000...4000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL5763-1DC36-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL630N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=630 A, Rated current IR=500...630A, Overload protection, II=3250...6500 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL6780-1SE36-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL800N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release ETU20, LSI In=800 A, Rated current Ir=320...800 A, Overload protection, ISD=1.5 to 7 xIr, II=8 xIn Short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL1704-1EH43-0AB1

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=40 A, Rated current Ir=40 A, Overload protection II=600 A, Short-circuit protection N unprotected without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL1796-2EH43-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL160X H High switching capacity Icu=70 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=16 A, Rated current Ir=16 A, Overload protection II=300 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL2706-2EJ43-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=63 A, Rated current Ir=50...63 A, Overload protection, II=300...600 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL1702-2EH43-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL160X H High switching capacity Icu=70 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=20 A, Rated current Ir=20 A, Overload protection II=300 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL2712-2EJ43-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=125 A, Rated current Ir=100...125 A, Overload protection, II=625...1250 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL4740-2EJ46-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL400H High switching capacity Icu=70 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=400 A, Rated current Ir=320...400 A, Overload protection, II=2000...4000 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL4731-2EJ46-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL400H High switching capacity Icu=70 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=315 A, Rated current Ir=250...315 A, Overload protection, II=1575...3150 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL4731-2DK36-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL400H High switching capacity Icu=70 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=315 A, Rated current II=2000...4000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL3725-2DK36-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=250 A, Rated current II=1750...3500 A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL1102-2KM30-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B020) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<20 A rated current II=300 A Short-circuit protection Ir=20 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch

3VL1105-2KM30-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B050) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<50 A rated current II=600 A Short-circuit protection Ir=50A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch

3VL1125-2KM30-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B025) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<25 A rated current II=300 A Short-circuit protection Ir=25 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch

3VL2515-2KN32-0AA0

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150 UL Type DG (CAT NO. HDK3B150U) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release TM, LI TU=40 °C In=150 A, Rated current II=800...1600 A Short-circuit protection Ir=150 A overcurrent release for system protection with connecting terminals Load side (LOAD) without auxiliary release without auxiliary/alarm switch

3VL2506-2PE30-0AD1

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150 UL Type DG (CAT NO. HDK3T060) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release ETU, LSI TU=40 °C In=60A, Rated current ISD=1.5-10xIR, II=11xIn Short-circuit protection Ir=30-60 A overcurrent release for system protection without connection accessories Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL2510-2PE30-0AD1

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150 UL Type DG (CAT NO. HDK3T100) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release ETU, LSI TU=40 °C In=100 A, Rated current ISD=1.5-10xIR, II=11xIn Short-circuit protection Ir=40-100 A overcurrent release for system protection without connection accessories Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL2515-2PE30-0AD1

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150 UL Type DG (CAT NO. HDK3T150) non-interchangeable frame, with approval circuit breaker according to UL 489 High switching capacity 3-pole; NEMA rating 65 kA @ 480 V and 18 kA @ 600/347 V (molded case circuit breaker) Overcurrent release ETU, LSI TU=40 °C In=150 A, Rated current ISD=1.5-10xIR, II=11xIn Short-circuit protection Ir=60-150A overcurrent release for system protection without connection accessories Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL1102-2KM30-0AD1

[Add to Enquire List] [Remove from Inquiry List] Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B020) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 High switching capacity 3-pole, NEMA rating 65 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<20 A rated current II=300 A Short-circuit protection Ir=20 A overcurrent release for system protection without connection accessories without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)