[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL1600N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release ETU20, LSI In=1600 A, Rated current IR=640...1600A, Overload protection, ISD=1.5 to 8 xIR, II=9 xIn Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=160 A, Rated current Ir=125...160 A, Overload protection, II=800...1600 A, short-circuit protection Shunt release 110...127 V AC Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=200A, Rated current Ir=160...200 A, Overload protection, II=1000...2000 A, short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU20, LSI In=400 A, Rated current Ir=160...400 A, Overload protection, ISD=1.5 to 10xIR, II=11xIn Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL1250N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release ETU10, LI In=1250 A, Rated current IR=500...1250A, Overload protection, II=1.25 to 10xIn, Short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL630N Standard switching capacity Icu=55 kA, 415V AC 3-pole, starter combination Overcurrent release magnetic In=500 A, Rated current II=3250...6300 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=250 A, Rated current Ir=200...250 A, Overload protection, II=1200...2500 A, short-circuit protection Undervoltage release 24 V DC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150X UL, Type CG (CAT NO. NCX3B030) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 Standard switching capacity 3-pole, NEMA rating 35 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<30 A rated current II=300 A Short-circuit protection Ir=30 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL150X UL Type CG (CAT NO. NCX3B020) non-interchangeable frame, with Approbation Circuit Breaker according to UL 489 Standard switching capacity 3-pole, NEMA rating 35 kA/480 V (molded case circuit breaker) Overcurrent release TM, LI function TU=40 °C In=<20 A rated current II=300 A Short-circuit protection Ir=20 A overcurrent release for system protection without connection accessories without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 630H
HIGH BREAKING CAPACITY
ICU=70KA / 415 V AC
3 POLE, LINE PROTECTION
OVERCURRENT RELEASE
TM, LI
IN=630A, RATED CURRENT
IR=500-630A, OVERLOAD
II=3250-6500A, SHORT CIRCUIT
WITHOUT AUXILIARY RELEASE
AUXILIARY/ALARM SWITCH KIT
2HS(1NO+1NC)+1AS(1NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL1600N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release ETU20, LSI In=1600 A, Rated current IR=640...1600A, Overload protection, ISD=1.5 to 8 xIR, II=9 xIn Short-circuit protection Shunt release 208...277 V AC Auxiliary switch mounting kit 4 AUX (2 NO + 2 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=16 A, Rated current Ir=16 A, Overload protection II=300 A, Short-circuit protection with screw terminal without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU12, LIG 3 phases/3 cables In=200A, Rated current IR=80...200A, Overload protection, II=1.25 to 11xIn, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=125 A, Rated current Ir=100...125 A, Overload protection II=1000 A, Short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=50 A, Rated current Ir=40...50 A, Overload protection II=300...600 A, Short-circuit protection protection, with screw terminal without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release LCD ETU40, LI/LS/LSI In=250 A, Rated current Ir=100...250 A, Overload protection, ISD=1.5 to 10xIR, II=11xIn Short-circuit protection with box terminal without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 3-pole, motor protection Overcurrent release ETU30M, LI IR=63...160A, Overload protection, TC=10 A...30, II=6/8/11 xIn, Short-circuit protection without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL160N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=160 A, Rated current Ir=125...160 A, Overload protection, II=800...1600 A, Short-circuit protection N unprotected with screw terminal without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=315 A, Rated current Ir=250...315 A, Overload protection, II=1575...3150 A, Short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch
[Add to Enquire List] [Remove from Inquiry List]Circuit breaker VL400N Standard switching capacity Icu=55 kA, 415V AC 4-pole, non-automatic air circuit breaker Overcurrent release magnetic In=400 A, Rated current II=4000 A, Short-circuit protection without auxiliary release without auxiliary/alarm switch