• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL400N

Showing 1-20 of 80 Products

3VL4720-1EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=200A, rated current IR=160...200A, overload protection, II=1000...2000A, short-circuit protection N protected

3VL4720-1EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=200A, rated current IR=160...200A, overload protection, II=1000...2000A, short-circuit protection N unprotected

3VL4720-1EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit, TM, LI In=200A, rated current IR=160...200A, overload prot. II=1000...2000A, short-circuit protection N protected (100%)

3VL4725-1EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1200...2500A, short-circuit protection N protected

3VL4725-1EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1250...2500A, short-circuit protection N unprotected

3VL4725-1EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit, TM, LI In=250A, rated current IR=200...250A, overload prot. II=1250...2500A, short-circuit protection N protected (100%)

3VL4731-1BA46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=315A, RATED CURRENT IR=128-315A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED

3VL4731-1BB46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=315A, RATED CURRENT IR=128-315A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N NOT PROTECTED

3VL4731-1BC46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=315A, RATED CURRENT IR=128-315A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N NOT PROTECTED

3VL4731-1BD46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=315A, RATED CURRENT IR=128-315A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED

3VL4731-1BE46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=315A, RATED CURRENT IR=128-315A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED

3VL4731-1BF46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=315A, RATED CURRENT IR=128-315A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED

3VL4731-1BG46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=315A, RATED CURRENT IR=128-315A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED

3VL4731-1BH46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=315A, RATED CURRENT IR=128-315A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED

3VL4731-1CJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected

3VL4731-1CN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection

3VL4731-1EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection N protected

3VL4731-1EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection N unprotected

3VL4731-1EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit, TM, LI In=315A, rated current IR=250...315A, overload prot. II=1575...3150A, short-circuit protection N protected (100%)

3VL4731-1LA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LI In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL