Circuit Breaker VL400N

Showing 41-60 of 80 Products

3VL4731-1UN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection

3VL4732-1EJ46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=45KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=315A, RATED CURRENT IR=250-315A, OVERLOAD II=1575-3150A, SHORT CIRCUIT N NOT PROTECTED

3VL4740-1AA44-0AA0

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N WITHOUT OVERCURRENT RELEASE STANDARD SWITCHING CAPACITY ICU=45KA / 415 V AC 4 POLE IN= < 400A, RATED CURRENT WITHOUT AUXILIARY RELEASE

3VL4740-1AA46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 4-pole In=< 400A, rated current without auxiliary release with screw terminal connections for switching unit and Electronic Trip Unit

3VL4740-1BA46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED

3VL4740-1BB46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N NOT PROTECTED

3VL4740-1BC46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N NOT PROTECTED

3VL4740-1BD46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED

3VL4740-1BE46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED

3VL4740-1BF46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED

3VL4740-1BG46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED

3VL4740-1BH46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED

3VL4740-1CJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected

3VL4740-1CN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection

3VL4740-1EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...4000A, short-circuit protection N protected

3VL4740-1EE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, non-auto. air circ. br. trip unit magnetic In=400A, rated current II=4000A, short-circuit protection

3VL4740-1EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...4000A, short-circuit protection N unprotected

3VL4740-1EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection TU, TM, LI In=400A, rated current IR=320...400A, overload prot. II=2000...4000A, short-circuit protection N protected (100%)

3VL4740-1LA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL

3VL4740-1LF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL