[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. NLX3N400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. NLX3X400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. NLX3P400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. NLX3U400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. NLX3D400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. NLX3E400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL; type LG (cat no. NLX3B400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 400A, rated current II=2000...4000A short-circuit protection IR=400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL; type LG (cat no. NLK3R400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LI TA=40?C In=400A, rated current II=1.25 to 11xIN, short-circuit protection IR=150-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL; type LG (cat no. NLK3W400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=400A, rated current II=1.25 to 11xIN, short-circuit protection IR=150-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL; type LG (cat no. NLK3T400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=400A, rated current ISD=1.5 to 10xIR, II=11 xIN short-circuit protection IR=200-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL; type LG (cat no. NLK3V400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.5 to 10xIR, II=11X in short-circuit protection IR=200-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL type LG (cat no. NLK3A400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL type LG (cat no. NLK3K400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400X UL type LG (cat no. NLK3G400) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 18kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=400A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=150-400A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3N400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3X400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3P400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3U400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3D400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 400A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400X UL; TYPE LG (CAT NO. HLX3E400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V AND 18KA//600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 400A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 150-400A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES