7MB2123-0CW27-1CA1

7MB2123-0CW27-1CA1

Manufacturer: SIEMENS

Price: On Request

2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO2 Smallest measuring range: 0 to 30 %, largest measuring range: 0 to 100 % With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 and PROFIBUS DP interface 200 to 240 V AC, 48 to 63 Hz CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm English


Similar items in same category:
7MB2123-0AL03-1PG1 7MB2123-0AL03-1PG1 2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 200 to 240 V AC, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 500 vpm, largest measuring range: 0 to 5000 vpm English
7MB2123-0AL03-1PG2 7MB2123-0AL03-1PG2 2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 200 to 240 V AC, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 500 vpm, largest measuring range: 0 to 5000 vpm French
7MB2123-0AT00-1CT1 7MB2123-0AT00-1CT1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 50 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz CO2 Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 50 % English
7MB2123-0BM00-1PG1 7MB2123-0BM00-1PG1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO highly selective (with optical filter) Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 500 vpm, largest measuring range: 0 to 5000 vpm English
7MB2123-0DM00-1NF1 7MB2123-0DM00-1NF1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CH4 Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz SO2 (TÜV) Smallest measuring range: 0 to 300 vpm, largest measuring range: 0 to 3000 vpm English
7MB2123-0ME00-1PG1 7MB2123-0ME00-1PG1 ULTRAMAT 6 GAS ANALYZER DUAL-CHANNEL 19" UNIT FOR INSTALLATION IN CABINETS GAS CONNECTION: STAINLESS STEEL STUB, 6 MM OD CHANNEL 1: MEASURED COMPONENT C SMALLEST MEASURING RANGE 0 TO 100 VPM LARGEST MEASURING RANGE 0 TO 1000 VPM INTERNAL GAS PATH:FPM (VITON) TUBING;SAMPLE CELL (LINING): ALUMINIUM;REFERENCE PART OF MEASURING CHAMBER NON-FLOWING- REFERENCE-SIDE WITHOUT ADDITIONAL ELECTRONICS (AUTOCALBOARD) POWER SUPPLY: AC 200 TO 240 V, 48 TO 63 HZ CHANNEL 2: MEASURED COMPONENT NO SMALLEST MEASURING RANGE 0 TO 500 VPM LARGEST MEASURING RANGE 0 TO 5000 VPM OPERATING SOFTWARE AND DOCUMENTATION: ENGLISH
7MB2123-0NP00-1NW3 7MB2123-0NP00-1NW3 2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter SO2 (TÜV) Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz SO2 (TÜV) Smallest measuring range: 0 to 30 %, largest measuring range: 0 to 100 % Spanish
7MB2123-0PE00-1ND1 7MB2123-0PE00-1ND1 2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter NO (TÜV) Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz SO2 (TÜV) Smallest measuring range: 0 to 50 vpm, largest measuring range: 0 to 1000 vpm English