• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MB2123-0AL03-1PG1

7MB2123-0AL03-1PG1

Manufacturer: SIEMENS

Price: On Request

2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 200 to 240 V AC, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 500 vpm, largest measuring range: 0 to 5000 vpm English


Similar items in same category:
7MB2121-1PE20-1AA1 7MB2121-1PE20-1AA1 ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 1/4" outer diameter NO (TÜV) Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm, With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz . . English
7MB2121-1PE21-1AA1 7MB2121-1PE21-1AA1 ULTRAMAT 6E gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 1/4" outer diameter NO (TUeV) Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm, . With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type AUTOCAL function with additionally each 8 binary input/outputs 200 to 240 V AC, 48 to 63 Hz . . English
7MB2123-.....-.... 7MB2123-.....-.... 2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components
7MB2123-0AB67-1AB1 7MB2123-0AB67-1AB1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample cell (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 and PROFIBUS DP interface 200 to 240 V AC, 48 to 63 Hz CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm English
7MB2123-0AL03-1PG2 7MB2123-0AL03-1PG2 2-Kanal ULTRAMAT6 gas analyzer two-channel 19" rack unit for installation in cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 200 to 240 V AC, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 500 vpm, largest measuring range: 0 to 5000 vpm French
7MB2123-0AT00-1CT1 7MB2123-0AT00-1CT1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 50 % Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz CO2 Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 50 % English
7MB2123-0BM00-1PG1 7MB2123-0BM00-1PG1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO highly selective (with optical filter) Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 500 vpm, largest measuring range: 0 to 5000 vpm English
7MB2123-0CW27-1CA1 7MB2123-0CW27-1CA1 2-Kanal ULTRAMAT 6, 19"Built-In gas analyzer cabinets for measuring 2 IR components Pipe with 6 mm outer diameter CO2 Smallest measuring range: 0 to 30 %, largest measuring range: 0 to 100 % With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs each for channel 1 and channel 2 and PROFIBUS DP interface 200 to 240 V AC, 48 to 63 Hz CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm English