• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL630N

Showing 1-20 of 43 Products

3VL5731-1DC36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection

3VL5731-1DK36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, starter combination trip unit magnetic In=315A, rated current II=2000...4000A, short-circuit protection

3VL5740-1DC36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=315...400A, overload protection, II=2000...4000A, short-circuit protection

3VL5750-1DC36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=500A, rated current IR=400...500A, overload protection, II=2500...5000A, short-circuit protection

3VL5750-1DK36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, starter combination trip unit magnetic In=500A, rated current II=3250...6300A, short-circuit protection

3VL5750-1LS36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL shipbuilding certificate for LRS, DNV and gL

3VL5750-1MP36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. trip unit ETU10M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 12.5xIN, short-circuit protection ETU communication-capable

3VL5750-1MP36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. trip unit ETU10M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 12.5xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL5750-1MS36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection ETU communication-capable

3VL5750-1MS36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL5750-1SP36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. trip unit ETU10M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 12.5xIN, short-circuit protection

3VL5750-1SS36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection

3VL5750-1UP36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. trip unit LCD ETU40M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 10xIN, short-circuit protection

3VL5750-1UP36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. trip unit LCD ETU40M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release

3VL5763-1DC36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=630A, rated current IR=500...630A, overload protection, II=3250...6500A, short-circuit protection

3VL5763-1DE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=630A, rated current II=6300A, short-circuit protection

3VL5763-1DK36-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU=45KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=630A, RATED CURRENT II=3250-6500A, SHORT CIRCUIT

3VL5763-1LB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL5763-1LE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL5763-1MB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection ETU communication-capable