• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL630H

Showing 1-20 of 47 Products

3VL5731-2EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection N protected

3VL5731-2EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection N unprotected

3VL5731-2EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection TU, TM, LI In=315A, rated current IR=250...315A, overload prot. II=1575...3150A, short-circuit protection N protected (100%)

3VL5732-2EJ46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=315A, RATED CURRENT IR=250-315A, OVERLOAD II=1575-3150A, SHORT CIRCUIT N NOT PROTECTED

3VL5740-2EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=400A, rated current IR=315...400A, overload protection, II=2000...4000A, short-circuit protection N protected

3VL5740-2EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=400A, rated current IR=315...400A, overload protection, II=2000...4000A, short-circuit protection N unprotected

3VL5740-2EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection TU, TM, LI In=400A, rated current IR=320...400A, overload prot. II=2000...4000A, short-circuit protection N protected (100%)

3VL5750-2EC46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=500A, rated current IR=400...500A, overload protection, II=2500...5000A, short-circuit protection N protected

3VL5750-2EJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=500A, rated current IR=400...500A, overload protection, II=2500...5000A, short-circuit protection N unprotected

3VL5750-2EM46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection TU, TM, LI In=500A, rated current IR=400...500A, overload prot. II=2500...5000A, short-circuit protection N protected (100%)

3VL5763-2AA46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H w/o Electronic Trip Unit high breaking capacity Icu=70kA/415V AC, 4-pole In=< 630A, rated current without auxiliary release with screw terminal connections for switching unit and ETU

3VL5763-2BA46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=630A, RATED CURRENT IR=252-630A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED

3VL5763-2BB46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=630A, RATED CURRENT IR=252-630A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N NOT PROTECTED

3VL5763-2BC46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=630A, RATED CURRENT IR=252-630A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N NOT PROTECTED

3VL5763-2BD46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=630A, RATED CURRENT IR=252-630A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED

3VL5763-2BE46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N NOT PROTECTED

3VL5763-2BF46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED

3VL5763-2BG46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N NOT PROTECTED

3VL5763-2BH46-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED

3VL5763-2CJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected