• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL400N

Showing 41-60 of 83 Products

3VL4731-1UP36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit LCD ETU40M, LI In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release

3VL4740-1DC36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...4000A, short-circuit protection

3VL4740-1DE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=400A, rated current II=4000A, short-circuit protection

3VL4740-1DK36-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU=45KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=400A, RATED CURRENT II=3000-6000A, SHORT-CIRCUIT

3VL4740-1DK36-0AA0

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400N STANDARD SWITCHING CAPACITY ICU= 45 KA, 415 V AC 3-POLE, STARTER COMBINATION OVERCURRENT RELEASE MAGNETIC IN= 400 A, RATED CURRENT II= 3000...6000 A, SHORT-CIRCUIT PROT. WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH

3VL4740-1LB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL4740-1LE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL4740-1MB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL4740-1MB36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL4740-1ME36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection ETU communication-capable

3VL4740-1ME36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection without auxiliary release ETU communication-capable

3VL4740-1MF36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL4740-1MF36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL4740-1MG36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection ETU communication-capable

3VL4740-1MG36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable

3VL4740-1MH36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection ETU communication-capable

3VL4740-1MH36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable

3VL4740-1ML36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL4740-1ML36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL4740-1SB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection