[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=315A, rated current IR=125...315A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=315A, rated current IR=125...315A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=125...315A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=125...315A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU20, LSI In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/4 lines In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU22, LSIG 3 phases/3 lines In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU22, LSIG 3 phases/4 lines with connecting cable In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU12, LIG 3 phases/3 lines In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=315A, rated current IR=125...315A, overload protection, II=1.25 to 11xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=125...315A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU42, LSIG 3 phases/3 lines In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU42, LSIG 3 phases/3 lines In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU42, LSIG 3 phases/4 lines with connecting cable In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU42, LSIG 3 phases/4 lines with connecting cable In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit LCD ETU40M, LI In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection