• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL400H

Showing 61-80 of 80 Products

3VL4740-2NA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected ETU communication-capable

3VL4740-2NA46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release ETU communication-capable

3VL4740-2NB46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL4740-2NB46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL4740-2NE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection ETU communication-capable

3VL4740-2NE46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection without auxiliary release ETU communication-capable

3VL4740-2NF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected ETU communication-capable

3VL4740-2NF46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL4740-2NH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected ETU communication-capable

3VL4740-2NH46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected without auxiliary release ETU communication-capable

3VL4740-2NN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected ETU communication-capable

3VL4740-2NN46-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release ETU communication-capable

3VL4740-2TA46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LIN In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected

3VL4740-2TB46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL4740-2TE46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N unprotected

3VL4740-2TF46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected

3VL4740-2TH46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected

3VL4740-2TN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected

3VL4740-2UJ46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected

3VL4740-2UN46-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected with ground-fault protection