[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU42, LSIG In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected with ground-fault protection
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=315A, RATED CURRENT IR=250-315A, OVERLOAD II=1575-3150A, SHORT CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H WITHOUT OVERCURRENT RELEASE HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE IN= < 400A, RATED CURRENT WITHOUT AUXILIARY RELEASE
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H w/o Electronic Trip Unit high breaking capacity Icu=70kA/415V AC, 4-pole In=< 400A, rated current without auxiliary release with screw terminal connections for switching unit and ETU
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 400H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected with ground-fault protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...4000A, short-circuit protection N protected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, non-auto. air circ. br. trip unit magnetic In=400A, rated current II=4000A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...4000A, short-circuit protection N unprotected
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection TU, TM, LI In=400A, rated current IR=320...400A, overload prot. II=2000...4000A, short-circuit protection N protected (100%)
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection N protected shipbuilding certificate for LRS, DNV and gL