• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL1600H

Showing 1-20 of 21 Products

3VL8716-2DE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=1600A, rated current II=14400A, short-circuit protection

3VL8716-2LB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL8716-2LE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL8716-2MB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection ETU communication-capable

3VL8716-2MB30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL8716-2ME30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection ETU communication-capable

3VL8716-2ME30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection without auxiliary release ETU communication-capable

3VL8716-2MF30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, protection, ETU communication-capable

3VL8716-2MF30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, protection, without auxiliary release ETU communication-capable

3VL8716-2MG30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection ETU communication-capable

3VL8716-2MG30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection without auxiliary release ETU communication-capable

3VL8716-2MH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection ETU communication-capable

3VL8716-2MH30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection without auxiliary release ETU communication-capable

3VL8716-2ML30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, protection, ETU communication-capable

3VL8716-2ML30-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, protection, without auxiliary release ETU communication-capable

3VL8716-2SB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection

3VL8716-2SE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection

3VL8716-2SF30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/4 lines In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, protection

3VL8716-2SG30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection

3VL8716-2SH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection