• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL150X UL

Showing 941-960 of 972 Products

3VL2706-3SB33-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL2705-3DC33-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, protection without auxiliary release without auxiliary/alarm switch

3VL6180-2KE30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. HMS3S800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) trip unit magnetic TA=40°C In=< 800A, rated current II=6500A short-circuit protection non-auto. air circuit breaker without connection accessories without auxiliary release without auxiliary/alarm switch

3VL1702-2EH46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=20A, rated current Ir=20A, overload protection II=300A, short-circuit prot. N unprotected with screw terminals without auxiliary release without auxiliary/alarm switch

3VL1703-2DD36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=32A, rated current Ir=32A, overload protection II=300A, short-circuit prot. with screw terminals without auxiliary release without auxiliary/alarm switch

3VL1704-2DD36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=40A, rated current Ir=40A, overload protection II=600A, short-circuit prot. with screw terminals without auxiliary release without auxiliary/alarm switch

3VL1706-2DD36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=63A, rated current Ir=63A, overload protection II=600A, short-circuit prot. with screw terminals without auxiliary release without auxiliary/alarm switch

3VL1712-2DD36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=125A, rated current Ir=125A, overload protection II=1000A, short-circuit prot. with screw terminals without auxiliary release without auxiliary/alarm switch

3VL1716-1EH43-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=160A, rated current Ir=160A, overload protection II=1500A, short-circuit prot. N unprotected without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL2706-2EJ46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection N unprotected with screw terminals without auxiliary release without auxiliary/alarm switch

3VL2706-3EJ46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection N unprotected with screw terminals without auxiliary release without auxiliary/alarm switch

3VL2716-1EJ43-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL2712-1EJ43-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=125A, rated current IR=100...125A, overload protection, II=625...1250A, short-circuit protection N unprotected without auxiliary release without auxiliary/alarm switch

3VL2705-1EJ43-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=50A, rated current Ir=40...50A, overload prot. II=300...600A, short-circuit protection, N unprotected N unprotected without auxiliary release without auxiliary/alarm switch

3VL2710-3SS33-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=40...100A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL4720-1DC36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=200A, rated current IR=160...200A, overload protection, II=1000...2000A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL1710-2DD33-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=100A, rated current Ir=100A, overload protection II=1000A, short-circuit prot. without auxiliary release without auxiliary/alarm switch

3VL2706-2DC36-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=63A, rated current IR=50...63A, overload protection, II=300...600A, short-circuit protection with screw terminals without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL2710-2DC36-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=100A, rated current IR=80...100A, overload protection, II=500...1000A, short-circuit protection with screw terminals without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL4731-2DK36-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=315A, rated current II=2000...4000A, short-circuit protection without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)