Circuit Breaker VL150X UL

Showing 921-940 of 972 Products

3VL1708-2DD33-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=80A, overload protection II=1000A, short-circuit prot. without auxiliary release without auxiliary/alarm switch

3VL2716-1EE43-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, non-auto. air circ. br. Trip Unit magnetic In=160A, rated current II=2500A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL3725-1SB36-8TD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection Shunt release 208...277 V AC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL1725-1DA33-0AB1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=25A, rated current Ir=25A, overload protection II=300A, short-circuit prot. without auxiliary release Auxiliary switch mounting kit 2 AUX (1 NO + 1 NC)

3VL1704-1DA33-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=40A, rated current Ir=40A, overload protection II=600A, short-circuit prot. without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL1708-1DA33-8TD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=80A, overload protection II=1000A, short-circuit prot. Shunt release 208...277 V AC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL4725-1DC36-0AD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1200...2500A, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL3725-1SE36-8TD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit ETU20, LSI In=250A, rated current IR=100...250A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection Shunt release 208...277 V AC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL4731-1LS36-8TA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=125...315A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL shipbuilding certificate for LRS, DNV and gL Shunt release 208...277 V AC without auxiliary/alarm switch

3VL5750-1LS36-8TE1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL shipbuilding certificate for LRS, DNV and gL Shunt release 208...277 V AC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL4740-1SE36-8TD1

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection Shunt release 208...277 V AC Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)

3VL4731-1EC46-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection N protected without auxiliary release without auxiliary/alarm switch

3VL2506-2PD30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150 UL type DG (cat no. HDK3W060) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit ETU, LIG TA=40°C 3 phases/4 lines In=60A, rated current II=1.25-11 xIN, short-circuit protection Ir=30-60A Electronic Trip Unit for line protection without connection accessories without auxiliary/alarm switch

3VL1107-1KM30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL150X UL, type CG (cat no. NCX3B070) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V (molded case circuit breaker) Electronic Trip Unit TM, LI function TA=40°C In=<70A rated current II=1000A short-circuit protection Ir=70A Electronic Trip Unit for line protection without connection accessories without auxiliary release without auxiliary/alarm switch

3VL5763-2DE36-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=630A, rated current II=6300A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3VL7180-2KN30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1200 UL; type NG (cat no. HNX3B800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40°C In=< 800A, rated current II=4000...8000A short-circuit protection IR=800A ETU for line protection without connection accessories without auxiliary release without auxiliary/alarm switch

3VL4860-2KE30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400X UL; type LG (cat no. HLR3S600) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V and 18kA/600V (molded case switch) trip unit magnetic TA=40°C In=< 600A, rated current II=5500A short-circuit protection non-auto. air circuit breaker without connection accessories without auxiliary release without auxiliary/alarm switch

3VL3520-2KN33-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL250 UL type FG (cat no. HFK3B200L) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65KA@480V and 18KA@600/347V (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=200A, rated current II=1000...2000A short-circuit protection IR=200A Electronic Trip Unit for line protection with terminals feeder and load-side (line and load) without auxiliary release without auxiliary/alarm switch

3VL6180-3PE30-0AA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL800 UL; type MG (cat no. LMX3T800) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LSI TA=40°C In=800A, rated current ISD=1.5 to 7xIR, II=8 xIn short-circuit protection IR=300-800A ETU for line protection without connection accessories without auxiliary release without auxiliary/alarm switch

3VL2716-2DC33-2PA0

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection Undervoltage release 24 V DC without auxiliary/alarm switch