Circuit Breaker VL1250N

Showing 1-20 of 52 Products

3VL7710-1LB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL7710-1LE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL7710-1MB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL7710-1MB36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL7710-1ME36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection ETU communication-capable

3VL7710-1ME36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection without auxiliary release ETU communication-capable

3VL7710-1MF36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL7710-1MF36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL7710-1MG36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection ETU communication-capable

3VL7710-1MG36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable

3VL7710-1MH36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection ETU communication-capable

3VL7710-1MH36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable

3VL7710-1ML36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL7710-1ML36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL7710-1SB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL7710-1SE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection

3VL7710-1SF36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/4 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL7710-1SG36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection

3VL7710-1SH36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection

3VL7710-1SL36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection