Circuit Breaker VL1250H

Showing 1-20 of 52 Products

3VL7710-2LB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL7710-2LE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection shipbuilding certificate for LRS, DNV and gL

3VL7710-2MB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL7710-2MB36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL7710-2ME36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection ETU communication-capable

3VL7710-2ME36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection without auxiliary release ETU communication-capable

3VL7710-2MF36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL7710-2MF36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL7710-2MG36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection ETU communication-capable

3VL7710-2MG36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable

3VL7710-2MH36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection ETU communication-capable

3VL7710-2MH36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable

3VL7710-2ML36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection ETU communication-capable

3VL7710-2ML36-0A..

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable

3VL7710-2SB36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL7710-2SE36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11 xIN short-circuit protection

3VL7710-2SF36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/4 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection

3VL7710-2SG36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection

3VL7710-2SH36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1000A, rated current IR=400...1000A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection

3VL7710-2SL36-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIG 3 phases/3 lines In=1000A, rated current IR=400...1000A, overload protection, II=1.25 to 11xIN, short-circuit protection