[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. HNX3D120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. HNX3E120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNS3S120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case switch) trip unit magnetic TA=40?C In=< 1200A, rated current II=12000A short-circuit protection non-auto. air circuit breaker without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNM3M120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (motor starter protector) trip unit magnetic TA=40?C In=< 1200A, rated current II=7000...12000A short-circuit protection starter combination without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3B120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1200A, rated current II=7000...12000A short-circuit protection IR=1200A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3R120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LI TA=40?C In=1200A, rated current II=1.25 to 10xIN, short-circuit protection IR=400-1200A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3W120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=1200A, rated current II=1.25 to 10xIN, short-circuit protection IR=400-1200A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3T120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=1200A, rated current ISD=1.5 to 10xIR, II=10xIN short-circuit protection IR=700-1200A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3V120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=1200A, rated current ISD=1.5 to 10xIR, II=10xIN short-circuit protection IR=700-1200A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. HNX3A120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. HNX3K120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. HNX3G120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3N120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3X120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3P120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3U120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3D120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3E120) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. LNS3S120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case switch) trip unit magnetic TA=40?C In=< 1200A, rated current II=12000A short-circuit protection non-auto. air circuit breaker without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. LNX3B120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1200A, rated current II=7000...12000A short-circuit protection IR=1200A ETU for line protection without connection accessories