[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3B100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1000A, rated current II=6000...10000A short-circuit protection IR=1000A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3R100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LI TA=40?C In=1000A, rated current II=1.25 to 11xIN, short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3W100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=1000A, rated current II=1.25 to 11xIN, short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3T100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=1000A, rated current ISD=1.5 to 10xIR, II=11 xIN short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3V100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=1000A, rated current ISD=1.5 to 10xIR, II=11 xIN short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. HNX3A100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=1000A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=400-1000A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. HNX3K100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=1000A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=400-1000A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. HNX3G100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=1000A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=400-1000A overcurrent rel. for line protection
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 1200 UL; TYPE NG (CAT NO. LNX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. HNX3B100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40?C In=< 1000A, rated current II=6000...10000A short-circuit protection IR=1000A ETU for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. LNX3R100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LI TA=40?C In=1000A, rated current II=1.25 to 11 xIn, short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. LNX3W100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40?C 3 phases/4 lines In=1000A, rated current II=1.25 to 11 xIn, short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. LNX3T100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LSI TA=40?C In=1000A, rated current ISD=1.5 to 10xIR, II=11 xIn short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL; type NG (cat no. LNX3V100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40?C 3 phases/4 lines In=1000A, rated current ISD=1.5 to 10xIR, II=11xIn short-circuit protection IR=400-1000A overcurrent rel. for line protection without connection accessories
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL1200 UL type NG (cat no. LNX3A100) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40?C In=1000A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=400-1000A overcurrent rel. for line protection