7SJ6021-5EB20-3FA0
Manufacturer: SIEMENS
Price: On Request
DIGITALER UEBERSTROMZEITSCHUTZ
SIPROTEC 7SJ602
OPTIONAL: MOTORSCHUTZ
OPTIONAL:
KOMMUNIKATIONSSCHNITTSTELLE
BINAEREINGABENSPG: 24 BIS 250V
MESSEINGAENGE (4 X I): IN = 1A
HILFSSPANNUNG:DC 110V BIS 250V,
AC 115V, 230V,
SCHWELLE BINAEREINGABE 88V
EINBAUGEHAEUSE,SCHRAUBKLEMMEN
(DIREKTANSCHL./RINGKABELSCHUHE)
SPRACHE ENGLISCH, DEUTSCH,
FRANZOESISCH, SPANISCH, 50/60HZ
IEC/ANSI-KURVEN, REGION WELT
SYSTEMSCHNITTSTELLE
GERAETEUNTERSEITE
IEC PROTOKOLL,ELEKTRISCH RS485
OHNE BEFEHL
MESSUNG:
STOERSCHREIBUNG, SCHLEPPZEIGER,
MITTELWERTE, MIN/MAX-WERTE,
FUNKTIONALITAET: XMZ+
UEBERSTROMZEITSCH.XMZ PH(50/51)
I>,I>>,IP, RUECKWAERTIGE VER-
RIEGELUNG, DREHFELDUNABHAENGIG
ERDKURZSCHLUSSSCHUTZ XMZ ERDE
(50N/51N: IE>, IE>>, IEP
UEBERLASTSCHUTZ MIT 2
ZEITKONSTANTEN (49)
AUSLOESEKREISUEBERWACHG.(74TC),
PARAMETERSATZUMSCHALTUNG MIT
TIMER (COLD LOAD PICKUP),
SCHIEFLASTSCHUTZ (46)
OHNE AUTOMAT. WIEDEREINSCHALTG.
Similar items in same category:
7SJ6021-5EB00-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB00-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB10-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS232 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB11-3HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS232 WITH COMMAND METERING: FAULT RECORDING, SLAVE POINTER, MEAN VALUES, MIN/MAX-VALUES FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB30-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, OPTICAL 820NM, ST-PLUG WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB80-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT THERMO-BOX, ELECTRICAL RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB91-1FA0 L0A | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT PROFIBUS DP SLAVE, ELECTR.RS485 WITH COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6022-.....-.... | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS (1 X V,3 X I): IPH = 1A, IE = SENSITIVE (IEE = 0.003 TO 1.5A) |