Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7SJ6021-5EB11-3HA0
Manufacturer: SIEMENS
Price: On Request
NUMERICAL OVERCURRENT-TIME
PROTECT. RELAY SIPROTEC 7SJ602
OPTIONAL: MOTOR PROTECTION
OPTIONAL: COMMUNICATION
INTERFACE BINARY INPUT
VOLTAGE:24 TO 250V MEASURING
INPUTS(4 X I): IN= 1A
SUPPLY VOLTAGE: DC 110 TO 250V,
AC 115V, 230V
TRIGGER LEVEL BINARY INPUT 88V
FLUSH MOUNTING, SCREW TERMINALS
(DIRECT WIRING/RING LUGS)
LANGUAGE ENGLISCH, GERMAN,
FRENCH, SPANISH, 50/60HZ
IEC/ANSI, REGION WORLD
SYSTEM PORT ON BOTTOM OF UNIT
IEC PROTOCOL, ELECTRIC RS232
WITH COMMAND
METERING: FAULT RECORDING,
SLAVE POINTER, MEAN VALUES,
MIN/MAX-VALUES
FUNCTIONALITY: TOC+ MOTOR PHASE
OVERCURRENT (50/51):
I>,I>>,IP,REVERSE INTERLOCKING,
INDEPENDENT OF PHASE ROTATION,
GROUND OVERCURRENT (50N/51N):
IE>, IE>>,IEP, OVERLOAD
PROTECTION WITH 2 TIME
CONSTANTS (49), TRIP CIRCUIT
SUPERVISION (74TC)
BREAKER-FAILURE PROTECT. (50BF)
COLD LOAD PICKUP, NEGATIVE
SEQUENCE (46), MOTOR
PROTECTION: START UP
SUPERVERSION (48),
UNDERCURRENT/LOSS OF LOAD
MONITORING (37), RESTART
INHIBIT (66/86)
WITHOUT AUTOMATIC RECLOSING
Similar items in same category:
7SJ6021-4EB80-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 48 TO 125V TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT THERMO-BOX, ELECTRICAL RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB00-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB00-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD WITHOUT SYSTEM INTERFACE WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB10-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, ELECTRIC RS232 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB20-3FA0 | DIGITALER UEBERSTROMZEITSCHUTZ SIPROTEC 7SJ602 OPTIONAL: MOTORSCHUTZ OPTIONAL: KOMMUNIKATIONSSCHNITTSTELLE BINAEREINGABENSPG: 24 BIS 250V MESSEINGAENGE (4 X I): IN = 1A HILFSSPANNUNG:DC 110V BIS 250V, AC 115V, 230V, SCHWELLE BINAEREINGABE 88V EINBAUGEHAEUSE,SCHRAUBKLEMMEN (DIREKTANSCHL./RINGKABELSCHUHE) SPRACHE ENGLISCH, DEUTSCH, FRANZOESISCH, SPANISCH, 50/60HZ IEC/ANSI-KURVEN, REGION WELT SYSTEMSCHNITTSTELLE GERAETEUNTERSEITE IEC PROTOKOLL,ELEKTRISCH RS485 OHNE BEFEHL MESSUNG: STOERSCHREIBUNG, SCHLEPPZEIGER, MITTELWERTE, MIN/MAX-WERTE, FUNKTIONALITAET: XMZ+ UEBERSTROMZEITSCH.XMZ PH(50/51) I>,I>>,IP, RUECKWAERTIGE VER- RIEGELUNG, DREHFELDUNABHAENGIG ERDKURZSCHLUSSSCHUTZ XMZ ERDE (50N/51N: IE>, IE>>, IEP UEBERLASTSCHUTZ MIT 2 ZEITKONSTANTEN (49) AUSLOESEKREISUEBERWACHG.(74TC), PARAMETERSATZUMSCHALTUNG MIT TIMER (COLD LOAD PICKUP), SCHIEFLASTSCHUTZ (46) OHNE AUTOMAT. WIEDEREINSCHALTG. | |
7SJ6021-5EB30-1FA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT IEC PROTOCOL, OPTICAL 820NM, ST-PLUG WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB80-1HA0 | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT THERMO-BOX, ELECTRICAL RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING | |
7SJ6021-5EB91-1FA0 L0A | NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT PROFIBUS DP SLAVE, ELECTR.RS485 WITH COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION GROUND OVERCURRENT (50N/51N) IE>, IE>>, IEP,OVERLOAD PROTEC. WITH 2 TIME CONSTANTS (49) TRIP CIRCUIT SUPERVISION (74TC) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46) WITHOUT AUTOMATIC RECLOSING |