[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit TM, LI In=315A, rated current IR=250...315A, overload protection, II=1575...3150A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, starter combination trip unit magnetic In=315A, rated current II=2000...4000A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=315...400A, overload protection, II=2000...4000A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit TM, LI In=500A, rated current IR=400...500A, overload protection, II=2500...5000A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, starter combination trip unit magnetic In=500A, rated current II=3250...6300A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. trip unit ETU10M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 10xIN, short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. trip unit ETU10M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection without auxiliary release ETU communication-capable
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. trip unit ETU10M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 12.5xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload prot., TC=10A...30, II=6/8/12.5xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. trip unit LCD ETU40M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 10xIN, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor/generator prot. trip unit LCD ETU40M, LI In=500A, rated current IR=200...500A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit TM, LI In=630A, rated current IR=500...630A, overload protection, II=3250...6500A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=630A, rated current II=6300A, short-circuit protection
[Add to Enquire List] [Remove from Inquiry List]CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=630A, RATED CURRENT II=3250-6500A, SHORT CIRCUIT
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection shipbuilding certificate for LRS, DNV and gL
[Add to Enquire List] [Remove from Inquiry List]circuit breaker VL630L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection ETU communication-capable