• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Unsorted

Showing 1-20 of 157219 Products

7VK6101-4AB22-4YC0

[Add to Enquire List] [Remove from Inquiry List] BREAKER MANAGEMENT RELAY CASE 1/3 19", 7BI, 6BO 1 WATCHDOG CONTACT FLUSH MOUNTING CASE, SCREW TERMINALS, MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) SUPPLY VOLTAGE: DC 60V TO 125V, BINARY INPUT OPERAT.VOLTAGE 19V LANGUAGE ENGLISH, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT, PORT B IEC PROTOCOL, RS485 DIGSI 4/MODEM PORT, PORT C DIGSI 4/ RS485 BREAKER-FAILURE PROTECTION 1-/3-POLE OR ONLY 3-POLE

7SJ8012-5EB00-1FA0

[Add to Enquire List] [Remove from Inquiry List] OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR

6DR5120-0NN00-0AA4

[Add to Enquire List] [Remove from Inquiry List] INTELLIGENT SIPART PS2 ELECTROPNEUMATIC POSITIONER FOR PNEUMATIC LINEAR AND PART-TURN ACTUATORS 2-WIRE; WITH HART-INTERFACE; DOUBLE ACTION; HOUSING: MAKROLON WITH FIXABLE SLIPPING CLUTCH. WITHOUT EX-APPROVALS; CONNECTION THREAD: EL.: 1/2 INCH NPT MEC.: 1/4 INCH NPT WITHOUT LIMIT MONITOR WITHOUT OPTION MODULE . INSTRUCTION MANUAL: GERMAN / ENGLISH . WITH MOUNTED GAUGE BLOCK, BLOCK MATERIAL: ALUMINIUM DOUBLE ACTING, NPT

7SJ6321-5EE92-3FG1 L0R

[Add to Enquire List] [Remove from Inquiry List] MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT GRAPHIC DISPLAY, 14 PROGRAMMABLE LED, KEY SWITCHES, CASE 1/2 19", 24BI, 11BO, 2 POWER RELAYS, (4 CONTACTS) 1 WATCHDOG CONTACT MEASURING INPUTS (3 X U,4 X I): IPH = 1A, IE = 1A(MIN. = 0.05A) SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS LANGUAGE SPANISH, REGION SP, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,RJ45-PLUG DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PAHSE ROTATION, GROUND OVERCURRENT (50/51N): IE>, IEE>>, IEP, DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N), PHASE ROTATION (47),OVERLOAD PROTECT. W.2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86), OVER/UNDER FREQU. (81U/O), UNDER VOLTAGE (27-1,27-2),OVER VOLTAGE (59-1) WITH AUTOMATIC RECLOSING

6MD6647-5EB92-0AA3 L0S

[Add to Enquire List] [Remove from Inquiry List] HIGH VOLTAGE BAY CONTROL UNIT HOUSING SIZE 1/1 7XP20 COMPONENTS: PROCESSOR MODULE WITH POWER SUPPLY INPUT/OUTPUT MODULES WITH: 65 SINGLE-POINT INDICATIONS 42 1-POLE SINGLE COMMANDS 3 SINGLE COMMAND TO COMMON POTENTIAL 1 LIVE CONTACT, APPLICABLE AS NO CONTACT OR NC CONTACT, 3 X CURRENT, 4 X VOLTAGE VIA DIRECT C.T. INPUTS 2 MEASURING TRANSDUCER INPUTS CURRENT TRANSFORMER 5A/ 200% IN AUXIL. VOLTAGE 220 TO 250V DC THRESHOLD BINARY INPUT 176V FLUSH-MOUNTING HOUSING, WITH INTEGRATED LOCAL OPERATION BACKGROUND ILLUMINATED GRAPHIC DISPLAY, 14 PROGRAMMABLE LEDS, KEY-OPERATED SWITCHES, CONTROL KEYS, NAVIGATION KEYS, FUNCTION KEYS, NUMERICAL BLOCK, SCREW-TYPE TERMINALS (DIRECT CONNECTION/ RING CABLE LUGS) REGION WORLD, 50/60HZ LANGUAGE: ENGLISH (LANGUAGE CAN BE CHANGED) IEC 61850, 100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) FUNCTION INTERFACE DIGSI 4, ELECTRIC RS485, PORT C WITH MEASURED-VALUE PROCESSING AND -DISPLAY WITH SYNCHRONIZATION PROTECTION FUNCTION: WITH AUTO-RECLOSURE AND CIRCUIT -BREAKER FAILURE PROTECTION INCL. FAULT RECORDING

9LS1001-0A

[Add to Enquire List] [Remove from Inquiry List] Hourly rate, 1 hour for TIB-door uprade

9LS1001-0B

[Add to Enquire List] [Remove from Inquiry List] Workpakage Color Touchscreen Upgrade Servicetask at customers site performed by a servicetech. for one Maxum, including side-cost and traveltime Scope of work: Integration Tochscreen / Syscon Backup, conversion and Check of the database Check Interface-Board Check operation software Check firmware Check devices functionality Time needed at site approx. one day

9LS1001-0D

[Add to Enquire List] [Remove from Inquiry List] Color Touchscreen Upgradekit for a MAXUM GC Content: - New color tochscreen door - Syscon 2.1 or retrofit kit - Ethernet switch board - Several cable and connector - Adapterplatte - Mounting-cage for Syscon - Small parts According to MAXUMs config. the package might differe When ordering specify: Serialnbr. of the device: SYSCON: SYSCON+ or 2.0 Software version workstation: Software version firmware:

9LS1001-0E

[Add to Enquire List] [Remove from Inquiry List] Value Add Service GC . The hourly rate is valid within Germany for working hours Mo-Fr (without public holidays) 7am-7pm. Waiting time will be charged like working time. Working time Mo-Fr (without public holidays) 7pm-7am, the 9th-11th daily hour and also on Saturday will be charged with a premium of 35%. Work from the 12th daily working hour as well as on Sundays and public holidays will be charged with a premium of 50%.

9LS1001-0F

[Add to Enquire List] [Remove from Inquiry List] Value Add Service GC: Service works 1 hour including 35% overtime

9LS1001-0G

[Add to Enquire List] [Remove from Inquiry List] Value Add Service GC: Service works 1 hour including 50% overtime

9LS1001-0H

[Add to Enquire List] [Remove from Inquiry List] Travelcost 1 KM

9LS1001-0K

[Add to Enquire List] [Remove from Inquiry List] Value Add Service GC: Travel 1 hour

9LS1001-0L

[Add to Enquire List] [Remove from Inquiry List] all travel expenses as per receipts (flight, hotel, rental car, etc.), delegation cost (CPD), daily allowances, Visa, etc.

9LS1001-1A

[Add to Enquire List] [Remove from Inquiry List] Hourly rate, 1 hour for TIB-door uprade

9LS1001-1C

[Add to Enquire List] [Remove from Inquiry List] Workpakage Color Touchscreen Upgrade Servicetask at customers site performed by a servicetech. for one Maxum, exluding side-cost and traveltime Scope of work: Integration Tochscreen / Syscon Backup, conversion and Check of the database Check Interface-Board Check operation software Check firmware Check devices functionality Valid for service technician from Germany for European countries within the European Comunity (without Germany)

6DR4004-1ES

[Add to Enquire List] [Remove from Inquiry List] External Position Transmitter in an aluminum enclosure with potentiometer, without electronics, without pneumatic block, for separate mounting of position detection at the actuator. SIPART PS2 externally mounted in protected area (not Ex d). Prerequisite: SIPART PS2 with integrated Analog Input Module (AIM) as order option or retrofit with 6DR4004-6F/-8F.

6DR4004-1RP

[Add to Enquire List] [Remove from Inquiry List] Booster KIT for direct mounting, Single Acting, Aluminum, G 1/2 (Cv=2) Ex d

6DR4004-1RQ

[Add to Enquire List] [Remove from Inquiry List] Booster KIT for direct mounting, Single Acting, Aluminum, NPT 1/2 (Cv=2) Ex d

6DR711.-.....-....

[Add to Enquire List] [Remove from Inquiry List] SIPART PS100 Electropneumatic positioner with aluminum enclosure