• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.

Circuit Breaker VL400 UL

Showing 1-20 of 94 Products

3VL4125-1GB30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. NJX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-1GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. NJX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-1GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. NJX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-1GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. NJX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-1JH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. NJX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-1JM30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. NJX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-1KN30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. NJX3B250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40?C In=< 250A, rated current II=1250...2500A short-circuit protection IR=250A Electronic Trip Unit for line protection without connection accessories

3VL4125-1PB30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. NJX3R250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LI TA=40?C In=250A, rated current II=1.25 to 11xIN, short-circuit protection IR=70-250A Electronic Trip Unit for line protection without connection accessories

3VL4125-1PD30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. NJX3W250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LIG TA=40?C 3 phases/4 lines In=250A, rated current II=1.25 to 11xIN, short-circuit protection IR=70-250A Electronic Trip Unit for line protection without connection accessories

3VL4125-1PE30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. NJX3T250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LSI TA=40?C In=250A, rated current ISD=1.5 to 10xIR, II=11X in short-circuit protection IR=70-250A Electronic Trip Unit for line protection without connection accessories

3VL4125-1PH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL; type JG (cat no. NJX3V250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole, NEMA rating 35kA/480V, (molded case circuit breaker) Electronic Trip Unit ETU, LSIG TA=40?C 3 phases/4 lines In=250A, rated current ISD=1.5 to 10xIR, II=11X in short-circuit protection IR=70-250A Electronic Trip Unit for line protection without connection accessories

3VL4125-1VH30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. NJX3A250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LI/LS/LSI TA=40?C In=250A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=70-250A Electronic Trip Unit for line protection

3VL4125-1VJ30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. NJX3K250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG-G with alarm TA=40?C 3 phases/4 lines In=250A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=70-250A Electronic Trip Unit for line protection

3VL4125-1VM30-....

[Add to Enquire List] [Remove from Inquiry List] circuit breaker VL400 UL type JG (cat no. NJX3G250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) Electronic Trip Unit LCD ETU, LSIG TA=40?C 3 phases/4 lines In=250A, rated current ISD=1.25-10xIR, II=11X in short-circuit protection IR=70-250A Electronic Trip Unit for line protection

3VL4125-2GB30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-2GD30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-2GE30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-2GH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-2JH30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES

3VL4125-2JM30-....

[Add to Enquire List] [Remove from Inquiry List] CIRCUIT-BREAKER VL 400 UL; TYPE JG (CAT NO. HJX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES