Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7SJ8112-....
Manufacturer: SIEMENS
Price: On Request
UEBERSTROMZEITSCHUTZ, 3POLIG 5A 50HZ 1-10S
Similar items in same category:
7SJ81..-.....-.... | OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS | |
7SJ8100-0XX00 | 7SJ81 Time-overcurrent protection | |
7SJ8110-.... | UEBERSTROMZEITSCHUTZ, 3POLIG 5A 50HZ 0,3-2,5S | |
7SJ8111-.... | UEBERSTROMZEITSCHUTZ, 3POLIG 5A 50HZ 0,5-5S | |
7SJ8113-1EB90-3FA0 L0A | OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER/FORM C), 1 LIVE STATUS CONTACT 4 X LOW POWER CURRENT TRANSFORMER INPUT RATED AUXILIARY VOLTAGE DC 24V/ 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH STANDARD FRONT SYSTEM PORT, PORT B (AT BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTR.RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP SENSITIVE GROUND FAULT PROTECT. IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT . | |
7SJ8113-1EB90-3FA0 L0D | OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER/FORM C), 1 LIVE STATUS CONTACT 4 X LOW POWER CURRENT TRANSFORMER INPUT RATED AUXILIARY VOLTAGE DC 24V/ 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH STANDARD FRONT SYSTEM PORT, PORT B (AT BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP SENSITIVE GROUND FAULT PROTECT. IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT . | |
7SJ8113-1EB90-3FA0L0A | overcurrent protection for low-power current transformer, enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 change-over contacts), 1 live contact, 4 x low-power current transformer inputs rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B PROFIBUS DP slave, electrical RS485 measurement: fault recording, mean value formation, min./max. values, functionality: basic version, without automatic reclosing, without fault locator | |
7SJ8113-1EB90-3FA0L0D | overcurrent protection for low-power current transformer, enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 change-over contacts), 1 live contact, 4 x low-power current transformer inputs rated auxiliary power: 24 - 48 V DC, installation enclosure, screw terminals region world, IEC / ANSI, language English (can be changed), front membrane standard, system interface port B Modbus, electrical RS485 measurement: fault recording, mean value formation, min./max. values. functionality: basic version, without automatic reclosing, without fault locator |