7SJ8100-0XX00

7SJ8100-0XX00

Manufacturer: SIEMENS

Price: On Request

7SJ81 Time-overcurrent protection


Similar items in same category:
7SJ8081-5EB91-1FA0 L0S 7SJ8081-5EB91-1FA0 L0S Time overcurrent protection SIPROTEC 7SJ80
7SJ8082-1EB06-3FF0 7SJ8082-1EB06-3FF0 OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE: DC 24, 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: BASIC FUNCTIONALITY + DIRECTIONAL PHASE & GROUND OVERCURRENT, DIRECT. SENSITIVE GROUND FAULT, VOLTAGE A. FREQUENCY PROTECTION UNDERVOLTAGE CONTROLLED REACTIV POWER PROTECTION + DIRECTIONAL INTERMITTENT GROUND FAULT PROTECTION WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
7SJ8082-5EB90-3FC0 L0A 7SJ8082-5EB90-3FC0 L0A OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTR.RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY:TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N,IE>,IE>>, IE>>>,IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
7SJ81..-.....-.... 7SJ81..-.....-.... OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS
7SJ8110-.... 7SJ8110-.... UEBERSTROMZEITSCHUTZ, 3POLIG 5A 50HZ 0,3-2,5S
7SJ8111-.... 7SJ8111-.... UEBERSTROMZEITSCHUTZ, 3POLIG 5A 50HZ 0,5-5S
7SJ8112-.... 7SJ8112-.... UEBERSTROMZEITSCHUTZ, 3POLIG 5A 50HZ 1-10S
7SJ8113-1EB90-3FA0 L0A 7SJ8113-1EB90-3FA0 L0A OVERCURRENT PROTECTION RELAY FOR LOW POWER CURRENT TRANSFORMERS HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER/FORM C), 1 LIVE STATUS CONTACT 4 X LOW POWER CURRENT TRANSFORMER INPUT RATED AUXILIARY VOLTAGE DC 24V/ 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH STANDARD FRONT SYSTEM PORT, PORT B (AT BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTR.RS485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP SENSITIVE GROUND FAULT PROTECT. IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT .