• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7SJ6222-5ED00-3HF0

7SJ6222-5ED00-3HF0

Manufacturer: SIEMENS

Price: On Request

MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE FRENCH, REGION FR (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE


Similar items in same category:
7SJ6222-5EB11-3HF1 7SJ6222-5EB11-3HF1 "MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19"", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS232 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, RS232 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITH AUTOMATIC RECLOSING"
7SJ6222-5EB20-1HH0 7SJ6222-5EB20-1HH0 MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER, BACKFIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+ V/F MOTOR IEE+ SENSITIVE DIRECTIONAL GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, LOCK OUT (86) GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N) PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) NEG. SEQUENSE(46),STARTING TIME SUPERVISION (48),RESTART INHIB. UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE
7SJ6222-5EB90-1HF0 L0B 7SJ6222-5EB90-1HF0 L0B MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, 820NM FIBER DOUBLE RING, ST-PLUG WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE
7SJ6222-5EB92-1HF0 L0A 7SJ6222-5EB92-1HF0 L0A MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE
7SJ6225-.....-.... 7SJ6225-.....-.... MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A
7SJ6225-.B...-.... 7SJ6225-.B...-.... MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
7SJ6225-4EB00-1FC0 7SJ6225-4EB00-1FC0 MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY:TOC+DIRECT. TOC+ PHASE OVERCURRENT (50/51) I>,I>>,IP, REVERSE INTERLOCKING INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N), PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46) LOCK OUT (86) WITHOUT AUTO-RECLOSURE
7SJ6225-4EB00-1FE0 7SJ6225-4EB00-1FE0 MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER, BACKFIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGG.LEVEL BINARY INPUT DC 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY: TOC+V/F PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>,IE>>,IEP, OVERLOAD PROTECT. WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTEC. (50BF), COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86), OVER/UNDER FREQUENCY (81U/O), UNDER VOLTAGE (27-1,27-2), OVER VOLTAGE (59-1) WITHOUT AUTO-RECLOSURE