7SJ6222-5EB20-1HH0
Manufacturer: SIEMENS
Price: On Request
MULTIFUNCTION PROTECTIVE RELAY BAY CONTROLLER, BACKFIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS 485 WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+ V/F MOTOR IEE+ SENSITIVE DIRECTIONAL GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, LOCK OUT (86) GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N) PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) NEG. SEQUENSE(46),STARTING TIME SUPERVISION (48),RESTART INHIB. UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE
Similar items in same category:
7SJ6222-5EB00-1FF0 | "MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19"", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY:TOC+ +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) UNDERCURRENT(37) NEGATIVE SEQUENCE (46) HIGH-IMPEDANCE RESTRICTED EARTH FAULT (87N) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE" | |
7SJ6222-5EB02-1HF0 | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE | |
7SJ6222-5EB02-1HH0 | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: FAULT RECORDING FUNCTIONALITY: TOC+ DIRECTIONAL TOC+ V/F MOTOR IEE+ SENSITIVE DIRECTIONAL GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, LOCK OUT (86) GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) DIRECTIONAL TIME OVERCURRENT (67/67N WITH 50N/51N) PHASE ROTATION (47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) NEG. SEQUENSE(46),STARTING TIME SUPERVISION (48),RESTART INHIB. UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE | |
7SJ6222-5EB11-3HF1 | "MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19"", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC PROTOCOL, RS232 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, RS232 METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITH AUTOMATIC RECLOSING" | |
7SJ6222-5EB90-1HF0 L0B | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, 820NM FIBER DOUBLE RING, ST-PLUG WITHOUT DIGSI 4/MODEM PORT METERING: FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE | |
7SJ6222-5EB92-1HF0 L0A | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B PROFIBUS DP SLAVE, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, RS485 METERING: FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE | |
7SJ6222-5ED00-3HF0 | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 1A, SENSITIVE EARTH CURRENT TRANSF. SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V TO 230V, TRIGG.LEVEL BINARY INPUT DC 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE FRENCH, REGION FR (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT METERING: PEAK VALUES, AVERAGE METER, MIN/MAX-VALUES, FAULT RECORDING FUNCTIONALITY:TOC+V/F MOTOR +SENSITIVE DIRECT. GROUND FAULT PHASE OVERCURRENT (50/51): I>,I>>,IP, GROUND OVERCURRENT (50N/51N): IE>, IE>>, IEP, SENSITIVE DIRECTIONAL GROUND PROTECTION IEE(67N): IEE>,IEE>> GROUND VOLTAGE DISPLACEMENT(64) PHASE ROTATION(47), OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) BREAKER FAILURE PROTECT. (50BF) INRUSH BLOCKKING, LOCK OUT (86) MOTOR PROTECT.:UNDERCURRENT(37) NEGATIVE SEQUENCE (46) START UP SUPERVISION (48) RESTART INHIBIT (66/86) UNDER-/OVERVOLTAGE (27/59) UNDER-/OVERFREQUENCY (81O/U) WITHOUT AUTO-RECLOSURE | |
7SJ6225-.....-.... | MULTIFUNCTION PROTECTIVE RELAY WITH BACKLIT TEXT DISPLAY, 4 X 20 CHARACTERS, 7 PROGRAMMABLE LED, CASE 1/3 19", 11BI, 6BO, 1 WATCHDOG CONTACT PHASE CURRENT TRANSFORMER 5A |