7ML5423-1CA10-3CA0
Manufacturer: SIEMENS
Price: On Request
SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 100 PN 16, Type A, flat faced Antenna Extention: 50 mm (2 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminium, Epoxy paint, 2 x M20 x1.5 Communication/Output: 4-20mA HART, start-up at
Similar items in same category:
7ML5423-.....-.... | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). | |
7ML5423-1AA10-2CA1 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 50 PN 16, Type A, flat faced Antenna Extention: 50 mm (2 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose, CE, RED, RCM Pressure rating: 0.5 bar (7.25 psi)maximum | |
7ML5423-1AA10-3CA0 | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 50 PN 16, Type A, flat faced Antenna Extention: 50 mm (2 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminium, Epoxy paint, 2 x M20 x1.5 Communication/Output: 4-20mA HART, start-up at | |
7ML5423-1AA20-3CA1 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 50 PN 16, Type A, flat faced Antenna Extention: 100 mm (4 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminium, Epoxy paint, 2 x M20 x1.5 Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose, CE, RED, RCM Pressure rating: 0.5 bar (7.25 psi)maximum | |
7ML5423-1DA00-2CA0 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 150 PN 16, Type A, flat faced Antenna Extension: No antenna extension Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose, CE, RED, RCM Pressure rating: rating per pressure/temperature curves in instruction manual | |
7ML5423-1FB00-2CA0 | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): 2 inch ASME, 150 lb, flat faced Antenna Extension: No antenna extension Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at | |
7ML5423-1FB20-2CH0 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): 2 inch ASME, 150 lb, flat faced Antenna Extention: 100 mm (4 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: Flame Proof, ATEX II 1/2G Ex dmbia IIC T4 Ga/Gb, CE, RED, RCM; GOST-R Pressure rating: rating per pressure/temperature curves in instruction manual | |
7ML5423-1HB20-2CB1 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): 4 inch ASME, 150 lb, flat faced Antenna Extention: 100 mm (4 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose,CSA, FM, Industry Canada, FCC Pressure rating: 0.5 bar (7.25 psi)maximum |