Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7ML5423-1AA20-3CA1
Manufacturer: SIEMENS
Price: On Request
SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 50 PN 16, Type A, flat faced Antenna Extention: 100 mm (4 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminium, Epoxy paint, 2 x M20 x1.5 Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose, CE, RED, RCM Pressure rating: 0.5 bar (7.25 psi)maximum
Similar items in same category:
7ML5422-3FA30 | SITRANS LR 200, UNI-CONSTRUCTION POLYPROPYLENE ROD ANTENNA VERSION 2-WIRE, 6 GHZ PULSE RADAR LEVEL TRANSMITTER FOR CONTINUOUS MONITORING OF LIQUIDS AND SLURRIES IN STORAGE AND PROCESS VESSELS INCLUDING HIGH TEMPERATURE AND PRESSURE, TO A RANGE OF 20 M (66 FT). ENCLOSURE / CABLE INLET: ALUMINUM, EPOXY PAINTED, 2 X M20 X 1.5, POLYPROPYLENE ANTENNA TYPE - (MAX. 3 BAR PRESSURE AND +80 C): G 1-1/2 INCH ((BSPP), EN ISO 228-1) COMES WITH INTEGRAL 250 MM SHIELD APPROVALS: GENERAL PURPOSE, CE, R&TTE, C-TICK COMMUNICATION / OUTPUT: 4-20MA HART, START-UP AT <3.6MA . | |
7ML5423-.....-.... | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). | |
7ML5423-1AA10-2CA1 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 50 PN 16, Type A, flat faced Antenna Extention: 50 mm (2 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose, CE, RED, RCM Pressure rating: 0.5 bar (7.25 psi)maximum | |
7ML5423-1AA10-3CA0 | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 50 PN 16, Type A, flat faced Antenna Extention: 50 mm (2 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminium, Epoxy paint, 2 x M20 x1.5 Communication/Output: 4-20mA HART, start-up at | |
7ML5423-1CA10-3CA0 | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 100 PN 16, Type A, flat faced Antenna Extention: 50 mm (2 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminium, Epoxy paint, 2 x M20 x1.5 Communication/Output: 4-20mA HART, start-up at | |
7ML5423-1DA00-2CA0 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): DN 150 PN 16, Type A, flat faced Antenna Extension: No antenna extension Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: General Purpose, CE, RED, RCM Pressure rating: rating per pressure/temperature curves in instruction manual | |
7ML5423-1FB00-2CA0 | SITRANS LR 200, Flange Adapter/PTFE Rod Antenna Version 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): 2 inch ASME, 150 lb, flat faced Antenna Extension: No antenna extension Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at | |
7ML5423-1FB20-2CH0 | SITRANS LR200 Radar level transmitter with PTFE rod: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries. Antenna material: PTFE Process Connection Flat faced flanges (316L stainless steel): 2 inch ASME, 150 lb, flat faced Antenna Extention: 100 mm (4 inch) extension, PTFE Process Seal/Gasket: Integral Gasket, for FF flange process connections only, not for Antenna options 3,4,5,6 Enclosure/Cable inlet: Aluminum, Epoxy painted, 2 x 1/2" NPT, Communication/Output: 4-20mA HART, start-up at <3.6mA Approvals: Flame Proof, ATEX II 1/2G Ex dmbia IIC T4 Ga/Gb, CE, RED, RCM; GOST-R Pressure rating: rating per pressure/temperature curves in instruction manual |