7UT6131-2BB11-1AA0

7UT6131-2BB11-1AA0

Manufacturer: SIEMENS

Price: On Request

DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 19V REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS232, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT. VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS


Similar items in same category:
7UT6125-5EC22-1AA0 7UT6125-5EC22-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION US, 60/50HZ, IEC/ANSI, LANGUAGE US-ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING)
7UT6125-5EC23-1BA0 7UT6125-5EC23-1BA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 5A SUPPLY VOLTAGE:DC 110V TO 250V, AC 115V/230V, TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION US, 60/50HZ, IEC/ANSI, LANGUAGE US-ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER, 820NM FIBER, ST-PLUG BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC)
7UT613.-.....-.... 7UT613.-.....-.... DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE,
7UT613.-.B...-.... 7UT613.-.B...-.... DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM
7UT6131-2BE11-1AA0 7UT6131-2BE11-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, SURFACE MOUNTING CASE, TERMINALS ON TOP AND BOTTOM CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 19V REGION WORLD, EC/ANSI, LANGUAGE SPANISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS232, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT. VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
7UT6131-2EB01-1AA0 7UT6131-2EB01-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT. VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
7UT6131-2EB11-1AA0 7UT6131-2EB11-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS232, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT. VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS
7UT6131-2EB22-1AA0 7UT6131-2EB22-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR, SMALL BUSBARS AND SHORT CABLE, 4-LINE ALPHANUM.BACKLIT DISPLAY 14 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, NUMBER BLOCK, CASE 1/2 X 19", 5BI, 8BO, 1 WATCHDOG CONTACT, 11I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 24V TO 48V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING) WITHOUT ADDIT. VOLTAGE FUNCTION WITHOUT ADDITIONAL FUNCTIONS