• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7UT6121-4EB10-1BA0

7UT6121-4EB10-1BA0

Manufacturer: SIEMENS

Price: On Request

DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS232, WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC)


Similar items in same category:
7UT6121-4EB00-1AA0 7UT6121-4EB00-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING)
7UT6121-4EB00-1BA0 7UT6121-4EB00-1BA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC)
7UT6121-4EB01-1AA0 7UT6121-4EB01-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING)
7UT6121-4EB01-1BA0 7UT6121-4EB01-1BA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) NO SYSTEM PORT DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI4, BROWSER,ELECTRIC. RS232 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC)
7UT6121-4EB20-1AA0 7UT6121-4EB20-1AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING)
7UT6121-4EB20-1BA0 7UT6121-4EB20-1BA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, WITHOUT DIGSI 4/MODEM PORT BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC)
7UT6121-4EB22-1BA0 7UT6121-4EB22-1BA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING RESTRICTED EARTH FAULT LOW IMPEDANCE (87N) UMZ - 1-PHASE FOR RESTRICTED EARTH FAULT HIGH IMPEDANCE (87N W/O RESISTOR AND VARISTOR) SENSITIVE OVERCURR.-TIME PROT./ TANK PROTECTION (64) NEGATIVE SEQUENCE PROTECT. (46) BREAKER FAILURE PROTECT. (50BF) TRIP CIRCUIT SUPERVISION (74TC)
7UT6121-4EB22-4AA0 7UT6121-4EB22-4AA0 DIGITAL DIFFERENTIAL PROTECTION RELAY, FOR TRANSFORMER, GENERATORS, MOTOR AND SHORT CABLE 4-LINE ALPHANUM.BACKLIT DISPLAY 7 PROGRAMMABLE LED, NAVIGATION KEYS, FUNCTION KEYS, CASE 1/3 X 19", 3BI, 4BO, 1 WATCHDOG CONTACT, 7I, IEE, CURRENT TRANSFORMER: 1A SUPPLY VOLTAGE: DC 60V TO 125V, TRIGGER LEVEL BINARY INPUT 19V FLUSH MOUNTING CASE, SCREW TERMINALS (DIRECT WIRING/RING LUGS) REGION WORLD, 50/60HZ, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 60870-5-103 PROTOCOL, ELECTRICAL RS485, DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4, BROWSER OR THERMO-BOX, ELECTRICAL RS485 BASIS MEASURED VALUES, FAULT RECORDING + TRANSFORMER-MONITORING FUNCTION (CONNECTION ON THERMO-BOX, HOTSPOT IEC,OVERLOAD FACTOR) FUNCTIONALITY: DIFFERENTIAL PROTECTION, BASIC FUNCTION, DIFFERENTIAL PROTECTION TRANSFORMER, GENERATOR, MOTOR, BUSBAR, (87 T G M L), OVERLOAD PROTECTION FOR ONE PAGE (49), LOCK OUT (86), TIME OVERCURR.PROTECT.TOC PHASE (50/51): I>, I>>, IP (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC 3I0 (50/51): 3I0>, 3I0>>, 3I0P (INRUSH BLOCKING) TIME OVERCURR.PROTECT.TOC EARTH (50/51): IE>, IEE>>, IEP (INRUSH BLOCKING)