Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7SR2105-1.A12-0DA0
Manufacturer: SIEMENS
Price: On Request
ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79)
Similar items in same category:
7SR2104-1NA87-0CA0 | Argus-M Non-directional overcurrent protection Enclosure E8, 4 curr. trans., 19 BI / 16 BQ, 8 LED + 6 buttons Measuring inputs: 1/5A, 50/60HZ Auxiliary voltage 24 ... 250 V DC / 100 ... 230 V AC Threshold binary input: 88 V DC USB interface at the front, RS485 interface at the back, + opt. Ethernet duplex at the back Protocol: IEC 60870-5-103 and Modbus RTU and DNP 3.0 (adjustable and IEC 61850 Protection function: Standard version: | |
7SR2105-1.A11-0CA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS KEYS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION | |
7SR2105-1.A11-0DA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79) | |
7SR2105-1.A12-0CA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION | |
7SR2105-1.A21-0CA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION | |
7SR2105-1.A21-0DA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-3-105 AND MODBUS RTU (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79) | |
7SR2105-1.A22-0CA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION | |
7SR2105-1.A22-0DA0 | ARGUS-M NONDIRECT. OVERCURRENT RELAY CASE SIZE E12, 4 CT, 39 BINARY INP./ 16 BINARY OUTP. 32 LEDS KEYS MEASURING INPUT: 1/5A, 50/60HZ USB FRONT PORT, RS485 REAR PORT + REAR F/O ST CONNECTORS (X2) AND IRIG-B IEC 60870-5-103, MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) PROTECTION FUNCTION: STANDARD VERSION PLUS AUTORECLOSE (79) |