7ML5501-0AG11
Manufacturer: SIEMENS
Price: On Request
Pointek CLS100, stainless steel process connection Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, inter- faces, solids, liquids, slurries and foam . . Process connection: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Approvals: CSA/FM Class II and III, Div. 1, Groups E, F, G Device version: Integral cable version (PPS probe) Overfill Protection: WHG, German overfill protection
Similar items in same category:
7ML5501-0AA70 | Pointek CLS100 RF Capacitance point level switch, stainless steel process connection. Detects level and interface in liquids, solids, slurries and foam. Compact, with 100 mm (4 inch) insertion, adaptable sensitivity, with the ability to tune out build-up on probe. . . Process connection: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Approvals: general purpose Device version: Enclosure version (PPS probe), M20x1.5 cable inlet Overfill Protection: Not required | |
7ML5501-0AC30 | Pointek CLS100 RF Capacitance point level switch, stainless steel process connection. Detects level and interface in liquids, solids, slurries and foam. Compact, with 100 mm (4 inch) insertion, adaptable sensitivity, with the ability to tune out build-up on probe. . . Process connection: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Approval: CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 'C Device version: Enclosure version (PPS probe), 1/2 " NPT cable inlet Overfill Protection: Not required | |
7ML5501-0AC80 | Pointek CLS100 RF Capacitance point level switch, stainless steel process connection. Detects level and interface in liquids, solids, slurries and foam. Compact, with 100 mm (4 inch) insertion, adaptable sensitivity, with the ability to tune out build-up on probe. . . Process connection: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Approval: CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 'C Device version: Enclosure version with PVDF probe body, M20 x 1.5 cable inlet Overfill Protection: Not required | |
7ML5501-0AG10 | Pointek CLS100, stainless steel process connection Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, inter- faces, solids, liquids, slurries and foam . . Process connection: 3/4" NPT ((Taper), ANSI/ASME B1.20.1) Approvals: CSA/FM Class II and III, Div. 1, Groups E, F, G Device version: Integral cable version (PPS probe) Overfill Protection: Not required | |
7ML5501-0EA10 | Pointek CLS100, stainless steel process connection Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, inter- faces, solids, liquids, slurries and foam . . Process connection: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Approvals: general purpose Device version: Integral cable version (PPS probe) Overfill Protection: Not required | |
7ML5501-0EA30 | POINTEK CLS100, STAINLESS STEEL PROCESS CONNECTION COMPACT 2-WIRE INVERSE FREQUENCY SHIFT CAPACITANCE SWITCH FOR LEVEL DETECTION IN CONSTRICTED SPACES, INTER- FACES, SOLIDS, LIQUIDS, SLURRIES AND FOAM . . PROCESS CONNECTION: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) APPROVALS: GENERAL PURPOSE DEVICE VERSION: ENCLOSURE VERSION (PPS PROBE), 1/2 " NPT CABLE INLET OVERFILL PROTECTION: NOT REQUIRED | |
7ML5501-0EA70 | Pointek CLS100, stainless steel process connection Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, inter- faces, solids, liquids, slurries and foam . . Process connection: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Approvals: general purpose Device version: Enclosure version (PPS probe), M20x1.5 cable inlet Overfill Protection: Not required | |
7ML5501-0EC60 | Pointek CLS100 RF Capacitance point level switch, stainless steel process connection. Detects level and interface in liquids, solids, slurries and foam. Compact, with 100 mm (4 inch) insertion, adaptable sensitivity, with the ability to tune out build-up on probe. . . Process connection: R 1" ((BSPT), EN 10226/PT (JIS-T), JIS B 0203) Approval: CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 'C Device version: Enclosure version with PVDF probe body, (1/2" NPT cable inlet) Overfill Protection: Not required |