Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7MF4434-.....-....
Manufacturer: SIEMENS
Price: On Request
SITRANS P DS III / P410, PROFIBUS PA, transmitter for differential pressure and flow PN 32/160
Similar items in same category:
7MF4433-3DA02-2RB6-ZA02+E10+D12 | SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING INERT MEASURING ALL CLEANING GREASE-FREE SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD EXPLOSION PROTECTION EEX IA + EEX D + DUST (ATEX) ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW WITH STAINLESS STEEL MOUNTING BRACKET OXYGEN APPLICATION (WITH OXYGEN MEASUREMENT AND INERT LIQUID MAX. 100 BAR (1450 PSI) AT 60 DEGREES CEL.(140 DEGREE F)) DEGREE OF PROTECTION IP 68 (NOT WITH PLUG OR CABLE GLAND PG 13,5) | |
7MF4433-3DA22-1AB0 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling inert measuring all cleaning grease-free Span: PN 160 (MWP 2320 psi): 2,5 to 250 mbar (1.004 to 100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 without indicator | |
7MF4433-3EA02-2RB6-ZA02+E10+D12 | SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING INERT MEASURING ALL CLEANING GREASE-FREE SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD EXPLOSION PROTECTION EEX IA + EEX D + DUST (ATEX) ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW WITH STAINLESS STEEL MOUNTING BRACKET OXYGEN APPLICATION (WITH OXYGEN MEASUREMENT AND INERT LIQUID MAX. 100 BAR (1450 PSI) AT 60 DEGREES CEL.(140 DEGREE F)) DEGREE OF PROTECTION IP 68 (NOT WITH PLUG OR CABLE GLAND PG 13,5) | |
7MF4433-3EA22-1AB0 | SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling inert measuring all cleaning grease-free Span: PN 160 (MWP 2320 psi): 6 to 600 mbar (2.409 to 240.9 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: cable gland M20 x1.5 without indicator | |
7MF4434-1CA02-2AB1 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for differential pressure and flow PN 32/160 Measuring cell filling silicone normal cleaning Nominal measuring range: PN 160 (MWP 2320 psi): 60 mbar (24.09 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA) | |
7MF4434-1DA02-1AB6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for differential pressure and flow PN 32/160 Measuring cell filling silicone normal cleaning Nominal measuring range: PN 160 (MWP 2320 psi): 250 mbar (100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window | |
7MF4434-1DA02-1EB6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for differential pressure and flow PN 32/160 Measuring cell filling silicone normal cleaning Nominal measuring range: PN 160 (MWP 2320 psi): 250 mbar (100.4 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel Standard design . Ex nA/ic - Use in Zone 2 Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window | |
7MF4434-1DY02-1EB6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for differential pressure and flow PN 32/160 Measuring cell filling silicone normal cleaning Nominal measuring range: PN 160 (MWP 2320 psi): 250 mbar (100.4 inH2O), max. static pressure 160 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel Standard design . Ex nA/ic - Use in Zone 2 Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window |