Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7MF4034-1DA00-2AB1
Manufacturer: SIEMENS
Price: On Request
SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA)
Similar items in same category:
7MF4034-1BA10-2AB1 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 1 bar g (14.5 psi g), overload limit 6 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA) | |
7MF4034-1BY00-2AF6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 1 bar g (14.5 psi g), overload limit 6 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: M12 connectors (stainless steel), (not with explosion proof, Intrinsic safety and explosion-proof) Housing cover with window | |
7MF4034-1CC00-1AB7-ZY01+Y21 | SITRANS P DS III PROFIBUS PA, TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING NOMINAL MEASURING RANGE 4 BAR G (58 PSI G), OVERLOAD LIMIT 10 BAR DIAPHRAGM HASTELLOY MEASURING CELL HASTELLOY PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN NONE EXPLOSION PROTECTION ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 HOUSING COVER WITH WINDOW (DIGITAL INDICATOR VISIBLE, CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED) MEASURING RANGE TO BE SET SPECIFY IN PLAIN TEXT: Y01: ... UP TO ... MBAR, BAR, KPA, MPA, PSI ADJUSTMENT DIGITAL INDICATOR SPECIFY PLAIN TEXT Y21: MBAR, BAR, KPA, MPA,... | |
7MF4034-1DA00-1AB6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window | |
7MF4034-1DA10-1AC6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window | |
7MF4034-1DA10-2AB1 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing International version english inscription and documentation on cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 without visible digital indicator (digital display hidden, setting: mA) | |
7MF4034-1DC00-1AB7-ZY01+Y21 | SITRANS P DS III PROFIBUS PA, TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING NOMINAL MEASURING RANGE 16 BAR G (232 PSI G), OVERLOAD LIMIT 32 BAR DIAPHRAGM HASTELLOY MEASURING CELL HASTELLOY PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN NONE EXPLOSION PROTECTION ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 HOUSING COVER WITH WINDOW (DIGITAL INDICATOR VISIBLE, CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED) MEASURING RANGE TO BE SET SPECIFY IN PLAIN TEXT: Y01: ... UP TO ... MBAR, BAR, KPA, MPA, PSI ADJUSTMENT DIGITAL INDICATOR SPECIFY PLAIN TEXT Y21: MBAR, BAR, KPA, MPA,... | |
7MF4034-1DY00-1AB6 | SITRANS P DS III / P410, PROFIBUS PA, transmitter for pressure Measuring cell filling silicone oil, normal cleaning Nominal measuring range 16 bar g (232 psi g), overload limit 32 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window |