7MF4033-1EA13-1ED6-ZA02+A30+B11+T03

7MF4033-1EA13-1ED6-ZA02+A30+B11+T03

Manufacturer: SIEMENS

Price: On Request

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 0,63 ... 63 BAR G (9.14 ... 914 PSI G), OVERLOAD LIMIT 100 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: FEMALE THREAD 1/2-14 NPT HOUSING MADE OF STAINLESS STEEL PRECISION CASTING STANDARD DESIGN EX NA/NL - USE IN ZONE 2 ELECTRIC CONNECTION AND CABLE INLET: HAN 7D PLUG (NOT WITH EXPLOSION PROOF) HOUSING COVER WITH WINDOW WITH STAINLESS STEEL MOUNTING BRACKET PLUG HAN 7D (METAL, GRAY) PLATE INSCRIPTION: ENGLISH WITH MOUNTED MANIFOLD 7MF9011-4FA, PROCESS CONNECTION AT TRANSMITTER 1/2-14 NPT MALE PTFE GASKET AND PRESSURE TEST, CERTIFIED WITH A FACTORY CERTIFICATE ACC. EN10204-2.2


Similar items in same category:
7MF4033-1EA10-1DB6 7MF4033-1EA10-1DB6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design Explosion protection EEx d cenelec) Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window
7MF4033-1EA10-1NC6 7MF4033-1EA10-1NC6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design Explosion protection fm + csa Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4033-1EA10-2AB6 7MF4033-1EA10-2AB6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window
7MF4033-1EA10-2BA6 7MF4033-1EA10-2BA6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing International design english inscription and documentation as cd Explosion protection EEx ia Electric connection and cable inlet: screwed gland PG 13.5 Housing cover with window
7MF4033-1EA60-1AC6 7MF4033-1EA60-1AC6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt Housing cover with window
7MF4033-1EA60-1EB6 7MF4033-1EA60-1EB6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: Male thread 1/2-14NPT Die-cast aluminium housing Standard design Ex nA/ic - Use in Zone 2 Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window
7MF4033-1FA00-1AA6 7MF4033-1FA00-1AA6 SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning 1.6 to 160 bar g (23.2 to 2320 psi g), Overload limit 250 bar, Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: screwed gland PG 13.5 Housing cover with window
7MF4033-1FA00-1AB7-ZB11+Y01+Y15+Y21+C11 7MF4033-1FA00-1AB7-ZB11+Y01+Y15+Y21+C11 SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 1,6 ... 160 BAR G (23.2 ... 2320 PSI G), OVERLOAD LIMIT 250 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 HOUSING COVER WITH WINDOW (DIGITAL INDICATOR VISIBLE, CUSTOMIZED ADJUSTMENT SUPPLEMENT Y21 REQUIRED) PLATE INSCRIPTION: ENGLISH RANGE (LINEAR CHARACTERISTIC) SPECIFY IN PLAIN TEXT:, Y01:... TO ...MBAR,KPA,MPA,... STAINLESS STEEL TAG PLATE (MEASURING POINT DESCRIPTION) MAX.16 CHARACTER, SPECIFY IN PLAIN TEXT: ADJUSTMENT DIGITAL INDICATOR SPECIFY PLAIN TEXT Y21: MBAR, BAR, KPA, MPA,... QUALITY INSPECTION CERTIFICATE (FACTORY CALIBRATION) TO IEC 60770-2