• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MB2541-.....-....

7MB2541-.....-....

Manufacturer: SIEMENS

Price: On Request

CALOMAT 62 gas analyzer, 19" rack unit for installation in cabinets


Similar items in same category:
7MB2521-1GA07-1AB1 7MB2521-1GA07-1AB1 Gas analyzer CALOMAT 6E 19-inch rack unit for installation in cabinets Sample gas connections: Pipe with external diameter 1/4 inch H2 monitoring (turbo generators) Measured component: CO2 in air/ smallest measuring range: 0-100%; Measured component: H2 in CO2/ smallest measuring range: 0-100%; Measured component: H2 in air/ smallest measuring range: 80-100%; . with Autocal function With additionally 8 binary in- and outputs and PROFIBUS DP interface Auxiliary power: 200 V to 240 V AC, 48 to 63 Hz . Explosion protection: Certificate: ATEX II3G, combustible and non- flammable gases documentation and software in English
7MB2527-.....-.... 7MB2527-.....-.... CALOMAT 6E GAS ANALYZER 19" RACK UNIT FOR INSTALLATION IN CABINETS Special Application
7MB2531-.....-.... 7MB2531-.....-.... CALOMAT 62 gas analyzer, for field installation
7MB2537-.....-.... 7MB2537-.....-.... Calomat 62F, Special Application
7MB2547-.....-.... 7MB2547-.....-.... CALOMAT 62E, special application.
7MB2621-.....-.... 7MB2621-.....-.... SIPROCESS UV600 gas analyzer, incl. Gas module and barometric pressure compensation
7MB2621-1AD24-0CD1 7MB2621-1AD24-0CD1 SIPROCESS UV600 gas analyzer, incl. Gas module and barometric pressure compensation Gas connection: 6mm pipe, Swagelok, gas path: PTFE 1.UV measured component: NO, smallest measuring range: 0 to 50 ppmv (0 to 70 mg/m3), largest measuring range: 0 to 1000 ppmv (0 to 1250 mg/m3) 2.UV measured component: NO2, smallest measuring range: 0 to 50 ppmv (0 to 100 mg/m3), largest measuring range: 0 to 1000 ppmv (0 to 2000 mg/m3) 1 0 0 0 0 0 0 0 0 0 0 0 0 3. UV measured component: SO2, smallest measuring range: 0 to 50 ppmv (0 to 130 mg/m3), largest measuring range: 0 to 1000 ppmv (0 to 2600 mg/m3) English
7MB2621-2BB43-0XX1 7MB2621-2BB43-0XX1 SIPROCESS UV600 gas analyzer, incl. Gas module and barometric pressure compensation Gas connection: 6mm pipe, Swagelok, gas path: stainless steel 1.UV measured component: NO2, smallest measuring range: 0 to 20 ppmv (0 to 40 mg/m3), largest measuring range: 0 to 400 ppmv (0 to 800 mg/m3) 2.UV measured component: H2S, smallest measuring range: 0 to 50 ppmv (0 to 40 mg/m3), largest measuring range: 0 to 500 ppmv (0 to 800 mg/m3) 1 0 0 0 0 0 0 0 0 0 0 0 0 Without English