7MB2118-.....-....

7MB2118-.....-....

Manufacturer: SIEMENS

Price: On Request

U6 2R Special application


Similar items in same category:
7MB2112-1AA00-1AA1 7MB2112-1AA00-1AA1 Ultramat 6F-2R gas analysator for field mounting Ferrule screw connection for pipe, outer diameter 1/4" CO and NO Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm (for both measured components) Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without Standard unit and acc. To ATEX II 3G version (Zone 2): 200 to 240 V AC, 48 to 63 Hz Without ., English
7MB2112-1BA60-6AA1 7MB2112-1BA60-6AA1 Ultramat 6F-2R gas analysator for field mounting Ferrule screw connection for pipe, outer diameter 1/4" CO2 and CO Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm (for both measured components) Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without ATEX II 2G versions (Zone 1), incl. certificate: 100 to 120 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: continuous purging) Without ., English
7MB2117-.....-.... 7MB2117-.....-.... ULTRAMAT 6F, SPECIAL APPLICATION, FOR FIEL MOUNTING
7MB2117-1FM31-0AA1-ZA29+B04+E12 7MB2117-1FM31-0AA1-ZA29+B04+E12 ULTRAMAT 6F, SPECIAL APPLICATION, FOR FIEL MOUNTING FERRULE SCREW CONNECTION FOR PIPE, OUTER DIAMETER 1/4" MEASURED COMPONENT C2H4 SMALLEST MEASURING RANGE: 0 TO 5000 VPM LARGEST MEASURING RANGE: 0 TO 50000 VPM INTERNAL TUBING MADE OF TITAN SAMPLE CELL (LINING): TANTAL REFERENCE PART OF MEAS.CHAMBER: FLOWING-REFERENCE-SIDE. WITH ADDITIONAL ELECTRONIC FOR AUTOMATIC CALIBRATION OF ZERO AND SENSITIVITY(RELAIS OUTPUTS) POWER SUPPLY: AC 100V TO 120V; 48 TO 63 HZ WITHOUT INTERNAL HEATING OF THE PHYSICAL PART. . DOCUMENTATION AND SOFTWARE IN ENGLISH LANGUAGE. FLOWING-REFERENCE-SIDE WITH REDUCED FLOW, 1/4" KALREZ GASKETS IN SAMPLE GAS PATH CERTIFICATE: ATEX 100; II 2/3G EEX NRP ( EX ZONE 2)
7MB2121-.....-.... 7MB2121-.....-.... ULTRAMAT 6E gas analyzer, single-channel 19" rack unit for installation in cabinets
7MB2121-0AB20-0AA1 7MB2121-0AB20-0AA1 ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm, With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz . . English
7MB2121-0AB30-0AA1 7MB2121-0AB30-0AA1 ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm, With sample gas monitoring, internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): flow-type Without 100 to 120 V AC, 48 to 63 Hz . . English
7MB2121-0CA00-0AA1 7MB2121-0CA00-0AA1 ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm, Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz . . English