Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7MB2112-.....-....
Manufacturer: SIEMENS
Price: On Request
Ultramat 6F-2R gas analysator for field mounting
Similar items in same category:
7MB2111-1CM61-2AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO2 Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 50000 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs 100 to 120 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: leakage compensation) Without ., English | |
7MB2111-1CR60-6AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO2 Smallest measuring range: 0 to 3%, largest measuring range: 0 to 30 % Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: continuous purging) Without ., English | |
7MB2111-1DP60-0AA1 | ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CH4 Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 % Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz Without ., English | |
7MB2111-1DS20-0AA1 | ULTRAMAT 6 gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CH4 Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 15 % Internal gas path: Pipe made of titanium, sample chamber (lining): Tantalum, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz Without ., English | |
7MB2112-0BF20-0AA1 | Ultramat 6F-2R gas analysator for field mounting Ferrule screw connection for pipe, outer diameter 6 mm CO2 and CO Smallest measuring range: 0 to 3 %, largest measuring range: 0 to 30 % (for both measured components) Internal gas path: Pipe made of titanium, sample chamber (lining): Tantalum, reference chamber (flow-type): non-flow-type Without Standard unit and acc. To ATEX II 3G version (Zone 2): 100 to 120 V AC, 48 to 63 Hz Without ., English | |
7MB2112-1AA00-1AA1 | Ultramat 6F-2R gas analysator for field mounting Ferrule screw connection for pipe, outer diameter 1/4" CO and NO Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm (for both measured components) Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without Standard unit and acc. To ATEX II 3G version (Zone 2): 200 to 240 V AC, 48 to 63 Hz Without ., English | |
7MB2112-1BA60-6AA1 | Ultramat 6F-2R gas analysator for field mounting Ferrule screw connection for pipe, outer diameter 1/4" CO2 and CO Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm (for both measured components) Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without ATEX II 2G versions (Zone 1), incl. certificate: 100 to 120 V AC, 48 to 63 Hz , according to ATEX II 2G (operating mode: continuous purging) Without ., English | |
7MB2117-.....-.... | ULTRAMAT 6F, SPECIAL APPLICATION, FOR FIEL MOUNTING |