Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7MB2024-.....-....
Manufacturer: SIEMENS
Price: On Request
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2
Similar items in same category:
7MB2023-0EB40-1NR1 | ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum Internal gas path (both channels): pipe made of titanium, sample chamber (lining, ULTRAMAT channel): Tantalum, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without AC 200 to 240 V, 48 to 63 Hz SO2 (TÜV) Smallest measuring range: 0 to 3 %, largest measuring range: 0 to 30 % English | |
7MB2023-0EC31-1PE4 | ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Flow-type compensation branch: made of stainless steel, mat. No. 1.4571 With sample gas monitoring (both channels), internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber (flow-type, ULTRAMAT channel): flow-type AUTOCAL function with 8 additional digital inputs and outputs for OXYMAT channel AC 200 to 240 V, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm Italian | |
7MB2023-1AA00-0CR1 | ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without AC 100 to 120 V, 48 to 63 Hz CO2 Smallest measuring range: 0 to 3 %, largest measuring range: 0 to 30 % English | |
7MB2023-1EA20-0AF1 | ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 With sample gas monitoring (both channels), internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without AC 100 to 120 V, 48 to 63 Hz CO Smallest measuring range: 0 to 300 vpm, largest measuring range: 0 to 3000 vpm English | |
7MB2026-.....-.... | ULTRAMAT 6 GAS ANALYZER 19" UNIT FOR INSTALLATION IN CABINETS FOR COMBINED MEASUREMENT OF O2 AND IR-ACTIV COMPONENTS. SPECIAL APPLICATION | |
7MB2027-.....-.... | OXYMAT 6E GAS ANALYZER 19" RACK UNIT FOR INSTALLATION IN CABINETS SPECIAL APPLICATIO | |
7MB2028-.....-.... | U6E/O6E SPECIAL APPLICATION | |
7MB2041-.....-.... | Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets |