• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MB2024-.....-....

7MB2024-.....-....

Manufacturer: SIEMENS

Price: On Request

ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2


Similar items in same category:
7MB2023-0EB40-1NR1 7MB2023-0EB40-1NR1 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of tantalum Internal gas path (both channels): pipe made of titanium, sample chamber (lining, ULTRAMAT channel): Tantalum, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without AC 200 to 240 V, 48 to 63 Hz SO2 (TÜV) Smallest measuring range: 0 to 3 %, largest measuring range: 0 to 30 % English
7MB2023-0EC31-1PE4 7MB2023-0EC31-1PE4 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressure 3000 hPa Flow-type compensation branch: made of stainless steel, mat. No. 1.4571 With sample gas monitoring (both channels), internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber (flow-type, ULTRAMAT channel): flow-type AUTOCAL function with 8 additional digital inputs and outputs for OXYMAT channel AC 200 to 240 V, 48 to 63 Hz NO (TÜV) Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm Italian
7MB2023-1AA00-0CR1 7MB2023-1AA00-0CR1 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 0.5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 Internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without AC 100 to 120 V, 48 to 63 Hz CO2 Smallest measuring range: 0 to 3 %, largest measuring range: 0 to 30 % English
7MB2023-1EA20-0AF1 7MB2023-1EA20-0AF1 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 5% reference gas pressure 3000 hPa Non-flow-type compensation branch: made of stainless steel, mat. No. 1.4571 With sample gas monitoring (both channels), internal gas path (both channels): hose made of FKM (Viton), sample chamber (lining, ULTRAMAT channel): Aluminium, reference chamber (flow-type, ULTRAMAT channel): non-flow-type Without AC 100 to 120 V, 48 to 63 Hz CO Smallest measuring range: 0 to 300 vpm, largest measuring range: 0 to 3000 vpm English
7MB2026-.....-.... 7MB2026-.....-.... ULTRAMAT 6 GAS ANALYZER 19" UNIT FOR INSTALLATION IN CABINETS FOR COMBINED MEASUREMENT OF O2 AND IR-ACTIV COMPONENTS. SPECIAL APPLICATION
7MB2027-.....-.... 7MB2027-.....-.... OXYMAT 6E GAS ANALYZER 19" RACK UNIT FOR INSTALLATION IN CABINETS SPECIAL APPLICATIO
7MB2028-.....-.... 7MB2028-.....-.... U6E/O6E SPECIAL APPLICATION
7MB2041-.....-.... 7MB2041-.....-.... Gas Analyzer OXYMAT 64, 19" unit for installation in cabinets