7MB1943-6EB02
Manufacturer: SIEMENS
Price: On Request
EXMONITOR TOX H2S-50 GAS DETECTOR FOR HYDROGEN SULFIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-50PPM H2S OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER
Similar items in same category:
7MB1943-6EA76 | EEX FLASHER LAMP IP 66 FOR USE IN ATEX ZONES 1 AND 2, FOR INDOOR AND OUTDOOR INSTALLATION, TEMPERATURE RANGE: -20...+40 C, POWER SUPPLY 230 VAC, 50 HZ | |
7MB1943-6EA77 | EEX FLASHER LAMP IP 66 FOR USE IN ATEX ZONES 1 AND 2, FOR INDOOR AND OUTDOOR INSTALLATION, TEMPERATURE RANGE: -20...+40 C, POWER SUPPLY 24 VDC | |
7MB1943-6EB00 | EXMONITOR TOX O2-25 GAS DETECTOR FOR OXYGEN DEFICIENCY, VERSION FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384 MEASURING PRINCIPLE: ELECTROCHEM. CELL; MEASURING RANGE: 0-25% VOL O2 LINEAR OUTPUT SIGNAL 4-20MA TWO-WIRE-SYSTEM 24V DC; POWER SUPPLY FROM EVALUATION UNIT 8022 HOUSING MATERIAL: GRP IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER | |
7MB1943-6EB01 | EXMONITOR TOX CO-1000 GAS DETECTOR FOR CARBON MONOXIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-300PPM CO OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER | |
7MB1943-6EB03 | EXMONITOR TOX H2S-100 GAS DETECTOR FOR HYDROGEN SULFIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-100PPM H2S OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER | |
7MB1943-6EB04 | EXMONITOR TOX CL2-20 GAS DETECTOR FOR CHLORINE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-10PPM CL2 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER | |
7MB1943-6EB05 | EXMONITOR TOX H2-1000 GAS DETECTOR FOR HYDROGEN, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-1000PPM H2 OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER | |
7MB1943-6EB06 | EXMONITOR TOX HCN-100 GAS DETECTOR FOR HYDROGEN CYANIDE, FOR USE IN HAZARDOUS AREA ZONE 1 ACCORD. TO ATEX; II 2G EEX IA IIC T4 AND BVS 03 ATEX E 384; MEASURING PRINCIPLE: ELECTROCHEMICAL CELL WITH THREE ELECTRODES. MEASURING RANGE: 0-100PPM HCN OUTPUT SIGNAL: 4-20MA, LINEAR TWO-WIRE-SYSTEM: 24V DC POWER SUPPLY FROM EVALUATION UNIT 8022; HOUSING MATERIAL: GRP- POLYESTER; IP54; RECOMMENDED BARRIERS: ELECTRICAL ISOLATING AMPLIFIER |