• Language:
  •  
  •  
  •  
+49 (30) 93663981
Mon-Fri: 8:30am - 6:00pm
... best spare parts for automation and industry
Searching...
Nothing found.
[[ item.description.prodDescription ]]
* Search is limited to the first 500 results. Please refine your criteria if necessary.
7MB1943-6EA16

7MB1943-6EA16

Manufacturer: SIEMENS

Price: On Request

EXDETECTOR HC-100 SENSOR FOR MONITORING THE LEL OF FLAMMABLE GASES AND VAPORS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ZONES 1 AND 2), MEASURING RANGE 0 TO 100% LEL, OUTPUT SIGNAL: 4-20MA, LINEAR 3-WIRE SYSTEM: 24VDC+4-20MA+GR, POWER SUPPLY FROM EVAL. UNIT


Similar items in same category:
7MB1943-6EA11 7MB1943-6EA11 GASMONITOR TOX NO2-20 FOR NITROGEN DIOXIDE DETECTION, FOR USE IN GENERAL PURPOSE CLASSIFIED AREAS MEASURING PRINCIPLE: ELECTROCHEMICAL CELL THREE ELECTRODES PRINCIPLE MEAS. RANGE: 0-20 PPM NO2 OUTPUT SIGNAL: 4 - 20MA LINEAR POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA12 7MB1943-6EA12 GASMONITOR TOX NH3-200 FOR AMMONIA DETECTION, FOR USE IN GENERAL PURPOSE CLASSIFIED AREAS MEASURING PRINCIPLE: ELECTROCHEMICAL CELL THREE ELECTRODES PRINCIPLE MEAS. RANGE: 0-200 PPM NH3 OUTPUT SIGNAL: 4-20MA LINEAR POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA13 7MB1943-6EA13 GASMONITOR TOX NO-100 FOR NITROGEN MONOXIDE DETECTION, FOR USE IN GENERAL PURPOSE CLASSIFIED AREAS MEASURING PRINCIPLE: ELECTROCHEMICAL CELL THREE ELECTRODES PRINCIPLE MEAS. RANGE: 0-100 PPM NO OUTPUT SIGNAL: 4-20MA LINEAR POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA15 7MB1943-6EA15 Exmess hc3 sensor for monitoring of lel of flammable gases and vapors in potentially explosive atmospheres; explosion protection: ex s IIc t4 and T6 and report dtm: bvs no.92.y.6002 measuring range: 0 to 100lel measuring principle: catalytic combustion output signal: 4-20ma, linear one-man calibration housing for wall mounting three-wire system: 24V dc, 4-20ma, ground. power supply from the evaluation unit 8022 (separate order no)
7MB1943-6EA16-0A 7MB1943-6EA16-0A LEL EXMONITOR HC 100-M FOR HYDROGEN DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR HYDROGEN (H2) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA16-0B 7MB1943-6EA16-0B LEL EXMONITOR HC 100-M FOR METHANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR METHANE (CH4) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA16-0C 7MB1943-6EA16-0C LEL EXMONITOR HC 100-M FOR ETHANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR ETHANE (C2H6) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
7MB1943-6EA16-0D 7MB1943-6EA16-0D LEL EXMONITOR HC 100-M FOR PROPANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR PROPANE (C3H8) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54