7MB1943-6EA16-0G
Manufacturer: SIEMENS
Price: On Request
LEL EXMONITOR HC 100-M FOR N-HEXANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR N-HEXANE (C6H14) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54
Similar items in same category:
7MB1943-6EA16-0C | LEL EXMONITOR HC 100-M FOR ETHANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR ETHANE (C2H6) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0D | LEL EXMONITOR HC 100-M FOR PROPANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR PROPANE (C3H8) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0E | LEL EXMONITOR HC 100-M FOR BUTANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR BUTANE (C4H10) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0F | LEL EXMONITOR HC 100-M FOR N-PENTANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR N-PENTANE (C5H12) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0H | LEL EXMONITOR HC 100-M FOR N-HEPTANE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR N-HEPTANE (C7H16) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0J | LEL EXMONITOR HC 100-M FOR ETHYLENE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR ETHYLENE (C2H4) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0K | LEL EXMONITOR HC 100-M FOR ACETYLENE DETECTION FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% LEL INITIAL FACTORY CALIBRATION FOR ACETYLENE (C2H2) OUTPUT SIGNAL: 4-20MA LINEAR MEASURING PRINCIPLE: CATALYTIC COMBUSTION (HEAT OF REACTION MEASURING) POWER SUPPLY 24V DC, POWER FEED FROM EVALUATION UNIT 8022 (ADDITIONAL PURCHASE REQUEST) HOUSING MATERIAL: ALUMINIUM, PROTECTION RATING: IP54 | |
7MB1943-6EA16-0L | LEL GAS DETECTOR MODEL EXDETECTOR HC 100-M PRIMARY FACTORY CALIBRATION FOR ANOTHER COMBUSTIBLE GAS FOR USE IN HAZARDOUS AREAS ZONE 1 AND 2 ACCORD. TO ATEX MEASURING RANGE: 0-100% UEG OUTPUT SIGNAL: 4-20MA AMBIENT TEMPERATURE RANGE: FROM -20 TO +55 DEG C DEGREE OF PROTECTION: IP 54 MEASURING PRINCIPLE: CATALYTIC COMBUSTION SUPPLY VOLTAGE: DC 24 V FROM EVALUATION UNIT 8022. INFORM ABOUT CALIBRATION GAS. |