Searching...
Nothing found.
[[ item.description.prodDescription ]]
This Product is on your Inquiry List.
7MB1943-2FC02
Manufacturer: SIEMENS
Price: On Request
SAMPLE GAS PROBE ATEX PROTECTED 1GD/2GD T4 T130 C ACCORD. TO ATEX, WITH DOWNSTREAM FILTER AND WEATHERPROOF COVER, WITH EX- TERMINAL BOX, TEMPERATURE SELF REGULATING AT 80 DEG C, AMBIENT TEMPERATURE RANGE: FROM -20 TO 50 DEG C, MAX. OPERATING PRESSURE 6 BAR MAX. DUST CONTENT UP TO 2G/M3 SUPPLY VOLTAGE 115V 50/60HZ WITHOUT FILTER, WITHOUT PIPE ACCESSORIES TO BE ORDERED WITH SEPARATE ORDER NUMBERS
Similar items in same category:
7MB1943-2FA16 | UNHEATED EXTENSION PIPE FOR SAMPLE GAS PROBE TYP G3/4, MATERIAL 1.4571, LENGTH 500 MM | |
7MB1943-2FB01 | HEATED SAMPLE GAS PROBE WITH DOWNSTREAM FILTER AND WEATHERPROOF COVER, HEATING ADJUSTABLE AT THE INSTALLED CONTROLLER WITH HIGH AND LOW TEMPERATURE ALARM, TEMPERATURE CONTROL RANGE: FROM 50 TO 200 DEG C AMBIENT TEMPERATURE RANGE: FROM -20 TO +70 DEG C MAX. OPERATING PRESSURE 6 BAR MAX. DUST CONTENT UP TO 2G/M3 SUPPLY VOLTAGE 230V 50/60HZ WITHOUT FILTER, WITHOUT PIPE ACCESSORIES TO BE ORDERED WITH SEPARATE ORDER NUMBERS | |
7MB1943-2FB02 | HEATED SAMPLE GAS PROBE WITH DOWNSTREAM FILTER AND WEATHERPROOF COVER, HEATING ADJUSTABLE AT THE INSTALLED CONTROLLER WITH HIGH AND LOW TEMPERATURE ALARM, TEMPERATURE CONTROL RANGE: FROM 50 TO 200 DEG C AMBIENT TEMPERATURE RANGE: FROM -20 TO +70 DEG C MAX. OPERATING PRESSURE 6 BAR MAX. DUST CONTENT UP TO 2G/M3 SUPPLY VOLTAGE 115V 50/60HZ WITHOUT FILTER, WITHOUT PIPE ACCESSORIES TO BE ORDERED WITH SEPARATE ORDER NUMBERS | |
7MB1943-2FC01 | SAMPLE GAS PROBE ATEX PROTECTED 1GD/2GD T4 T130 C ACCORD. TO ATEX, WITH DOWNSTREAM FILTER AND WEATHERPROOF COVER, WITH EX- TERMINAL BOX, TEMPERATURE SELF REGULATING AT 80 DEG C, AMBIENT TEMPERATURE RANGE: FROM -20 TO 50 DEG C, MAX. OPERATING PRESSURE 6 BAR MAX. DUST CONTENT UP TO 2G/M3 SUPPLY VOLTAGE 230V 50/60HZ WITHOUT FILTER, WITHOUT PIPE ACCESSORIES TO BE ORDERED WITH SEPARATE ORDER NUMBERS | |
7MB1943-2FD00 | Pneumatic actuator spring loaded n.o. for shut of valve | |
7MB1943-2FD01 | Sample probe with manual shut off valve 230V AC, 50/60HZ, 400VA back flush connection, weather protection shield, cartridge heater, electronic controller with high and low temperature alarm outputs | |
7MB1943-2FD02 | Sample probe with manual shut off valve 115V AC, 50/60HZ, 400VA back flush connection, weather protection shield, cartridge heater, electronic controller with high and low temperature alarm outputs | |
7MB1943-2FE00 | EXTENSION OF SAMPLING PIPE12 (7MB1943-2FE12) STAINLESS STEEL 1.4571 L=1000 MM D=20X1,5 MM GAS TEMPERATURE UP TO 600 C WITHOUT CONNECTION FOR IN-SITU FILTER |