SIPROTEC 7SJ66

Multifunction protection relay with control and monitoring functions for high- and medium-voltage networks
Showing 1-15 of 28 Products
Sorted by article number
7SJ661.-.....-....
MULTIFUNCTION PROTECTIVE RELAY CASE 1/3 19", 4 X U, 4 X I, 16BI, 7BO,1 LIVE-STATUS CONTACT
7SJ661.-....0-....
Digital multifunction protection Enclosure 1/3 19", 4 x U, 4 x I, 16 BI, 7 BQ, 1 live contact Without DIGSI 4/modem interf.
HS 85363010 5,100 kg
7SJ661.-....2-....
digital multifunctional protection housing 1/3 19", 4 x U, 4 x I, 16BI, 7BO, 1 live contact DIGSI 4/modem interface rear of the device port C DIGSI 4/modem/RDT box, electrical RS485
HS 85363010 5,100 kg
7SJ661.-....6-....
digital multifunctional protection housing 1/3 19", 4 x U, 4 x I, 16BI, 7BO, 1 live contact interface rear of the device port C Ethernet port (DIGSI port, RTD box conn.,not IEC61850) RJ45 plug
HS 85363010 5,100 kg
7SJ6611-5EB90-1FA0
Digital multifunction protection Enclosure 1/3 19", 4 x U, 4 x I, 16 BI, 7 BQ, 1 live contact Without DIGSI 4/modem interf.
HS 85363010 5,100 kg
7SJ6611-5EB90-1FA0 L0R
MULTIFUNCTION PROTECTIVE RELAY CASE 1/3 19", 4 X U, 4 X I, 16BI, 7BO,1 LIVE-STATUS CONTACT MEASURING INPUTS (3 X U/ 4 X U, 4 X I) IPH = 1A, IN = 1A (MIN.= 0.05A) SUPPLY VOLTAGE: 110 TO 250V DC,115 TO 230V AC TRIGG.LEVEL BINARY INPUT DC 69V FLUSH MOUNTING CASE, SPRING TYPE TERMINALS (DIRECT CONNECTION) SCREW-TYPE TERMINALS FOR CT CONNECTION (DIREKT CONNECTION/ RING-TYPE CABLE LUGS), 8-LINE TEXT DISPLAY LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET ELECTRIC.,DOUBLE,RJ45-CONNECTOR WITHOUT DIGSI 4/MODEM PORT MEASURING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTORECLOSE WITHOUT FAULT LOCATOR WITHOUT SYNCHRONIZATION
HS 85363010 5,100 kg
7SJ6611-5EB92-1FA0
digital multifunctional protection housing 1/3 19", 4 x U, 4 x I, 16BI, 7BO, 1 live contact DIGSI 4/modem interface rear of the device port C DIGSI 4/modem/RDT box, electrical RS485
HS 85363010 5,100 kg
7SJ6611-5EB92-1FA0 L0D
MULTIFUNCTION PROTECTIVE RELAY CASE 1/3 19", 4 X U, 4 X I, 16BI, 7BO,1 LIVE-STATUS CONTACT MEASURING INPUTS (3 X U/ 4 X U, 4 X I) IPH = 1A, IN = 1A (MIN.= 0.05A) SUPPLY VOLTAGE: 110 TO 250V DC,115 TO 230V AC TRIGG.LEVEL BINARY INPUT DC 69V FLUSH MOUNTING CASE, SPRING TYPE TERMINALS (DIRECT CONNECTION) SCREW-TYPE TERMINALS FOR CT CONNECTION (DIREKT CONNECTION/ RING-TYPE CABLE LUGS), 8-LINE TEXT DISPLAY LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4/MODEM/ RTD-BOX, ELECTRICAL RS485 MEASURING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTORECLOSE WITHOUT FAULT LOCATOR WITHOUT SYNCHRONIZATION
HS 85363010 5,100 kg
7SJ6615-5EB90-1FA0
Digital multifunction protection Enclosure 1/3 19", 4 x U, 4 x I, 16 BI, 7 BQ, 1 live contact Without DIGSI 4/modem interf.
HS 85363010 5,100 kg
7SJ6615-5EB90-1FA0 L0R
MULTIFUNCTION PROTECTIVE RELAY CASE 1/3 19", 4 X U, 4 X I, 16BI, 7BO,1 LIVE-STATUS CONTACT MEASURING INPUTS (3 X U/ 4 X U, 4 X I) IPH = 5A, IN = 5A (MIN.= 0,25A) SUPPLY VOLTAGE: 110 TO 250V DC,115 TO 230V AC TRIGG.LEVEL BINARY INPUT DC 69V FLUSH MOUNTING CASE, SPRING TYPE TERMINALS (DIRECT CONNECTION) SCREW-TYPE TERMINALS FOR CT CONNECTION (DIREKT CONNECTION/ RING-TYPE CABLE LUGS), 8-LINE TEXT DISPLAY LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B IEC 61850,100 MBIT ETHERNET ELECTRIC.,DOUBLE,RJ45-CONNECTOR WITHOUT DIGSI 4/MODEM PORT MEASURING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTORECLOSE WITHOUT FAULT LOCATOR WITHOUT SYNCHRONIZATION
HS 85363010 5,100 kg
7SJ6615-5EB92-1FA0
digital multifunctional protection housing 1/3 19", 4 x U, 4 x I, 16BI, 7BO, 1 live contact DIGSI 4/modem interface rear of the device port C DIGSI 4/modem/RDT box, electrical RS485
HS 85363010 5,100 kg
7SJ6615-5EB92-1FA0 L0D
MULTIFUNCTION PROTECTIVE RELAY CASE 1/3 19", 4 X U, 4 X I, 16BI, 7BO,1 LIVE-STATUS CONTACT MEASURING INPUTS (3 X U/ 4 X U, 4 X I) IPH = 5A, IN = 5A (MIN.= 0,25A) SUPPLY VOLTAGE: 110 TO 250V DC,115 TO 230V AC TRIGG.LEVEL BINARY INPUT DC 69V FLUSH MOUNTING CASE, SPRING TYPE TERMINALS (DIRECT CONNECTION) SCREW-TYPE TERMINALS FOR CT CONNECTION (DIREKT CONNECTION/ RING-TYPE CABLE LUGS), 8-LINE TEXT DISPLAY LANGUAGE ENGLISH, 50/60HZ, IEC/ANSI, REGION WORLD, (LANGUAGE CHANGEABLE) SYSTEM PORT (ON REAR OF DEVICE) PORT B MODBUS, RS485 DIGSI 4/MODEM PORT (ON REAR OF DEVICE) PORT C DIGSI 4/MODEM/ RTD-BOX, ELECTRICAL RS485 MEASURING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECT.W. 2 TIME CONSTANTS(49) TRIP CIRCUIT SUPERVISION (74TC) UNDERCURRENT MONITORING (37), DISPLACEMENT VOLTAGE (59N/64), BREAKER FAILURE PROTECT. (50BF) COLD LOAD PICKUP, INRUSH BLOCKING, NEGATIVE SEQUENCE (46), LOCK OUT (86) WITHOUT AUTORECLOSE WITHOUT FAULT LOCATOR WITHOUT SYNCHRONIZATION
HS 85363010 5,100 kg
7SJ662.-.....-....
MULTIFUNCTION PROTECTIVE RELAY CASE 1/3 19", 4 X U, 4 X I, 22BI,10BO,1 LIVE-STATUS CONTACT
7SJ662.-....0-....
Digital multifunction protection Enclosure 1/3 19", 4 x U, 4 x I, 22BI, 10BQ, 1 live contact Without DIGSI 4/modem interf.
HS 85363010 5,100 kg
7SJ662.-....2-....
Digital multifunction protection Enclosure 1/3 19", 4 x U, 4 x I, 22BI, 10BQ, 1 live contact DIGSI 4/modem interface Rear of the device port C DIGSI 4/modem/ RTD box, electrical RS485
HS 85363010 5,100 kg
0